Presentation of your device
8
Installing your device
Installing your device
Presentation of your device
Neutral
(N)
Phase
(L)
Blue
wire
Green / yellow wire
Black, brown or
red wire
WARNING
The safety wire (green-yellow) is connected
to the appliance’s
terminal and must be
connected to the earth terminal of the elec-
trical set-up.
The fuse in your set-up must be 16 amperes.
ELECTRICAL CONNECTION
Your oven must be connected with a (standard)
power cable with 3 conductors of 1.5mm2 (1 live
+ 1 n earth) which must be connected to
a 220-240V~ single-phase grid by means of a 1
live + 1 n earth CEI 60083 standard power
socket or via an all-poles cut-off device in com
-
pliance with the installation rules.
We cannot be held responsible for any acci-
dent resulting from inexistent, defective or
incorrect earthing.