background image

16

LED LIGHT REPLACEMENT 

CHARCOAL FILTER REPLACEMENT

Remove the charcoal filter from the blower as shown.
Fit in the new charcoal fiter.

Before attempting to replace the light bulb, make sure that the light switch is 

turned off. Remove the grease filter to access the lamp area. Remove the 

damaged LED light and replace with a  LED light maximum 5 W.

16

Vent System

3

The length of the ductwork and the number of elbows should be kept to a 

minimum to optimise performance. The size of the ductwork should be 

uni- form. Do not install two elbows together. Ensure all joints in the 

ductwork system are sealed well. Use caulking to seal exterior wall 
or floor opening around the cap.

(e.g. charcoal filters) before use.

This product is intended for domestic use and the household environment 

only. The product is not intended for an outside use or in a commercial setting.

Do not leave the product unattended during operation. Brandt Asie Pte 

is not liable for damage caused by improper use or incorrect operation.

Determine which venting method is best for your application. Vented 
(non- recirculating) system terminates on the outside. Ductwork may

 be extended either through the wall or the roof. Do not terminate the

vent system in an attic or other enclosed area.

Cleaning & Maintenance

SURFACES : Wash with warm soapy water and a soft sponge. Never
use harsh or abrasive cleaning agents,cleaning agents with high alcohol 
content, hard scouring pads or cleaning sponges or high-pressure 

cleaners or steam cleaners on any part of this appliance as this will 
cause irreparable damage.

Summary of Contents for AD9905B

Page 1: ...AD9905B COOKER HOOD ...

Page 2: ......

Page 3: ...ent System Requirements Description of Parts Ducting vs Re circulating mode Re circulating mode air outlet Installation Electrical Connection Operation Auto Linkage System Cleaning Maintenance Troubleshooting Schematic Diagram Dimension Drawing 1 1 2 3 4 5 6 7 12 13 14 15 17 18 18 ...

Page 4: ...e and respect the environment Please help us to continue the protection of the environment by disposing of the packaging in a correct manner Safety Specifications Input Motor LED Light Total Power AC 220 240V 50Hz 1 5W 1 1 x 220 W 225 W Schematic Diagram Dimension drawing 18 Flow rate 1300m3 h 470 470 ...

Page 5: ...ce may be used safely if it is correctly installed according to the provided safety instruction by a qualified installer The installer is responsible for ensuring that the appliance works correctly at its installation location Brandt Asie Pte Ltd is not liable for damage caused by incorrect installation or connection and such damages are not covered under warranty It is dangerous to modify any par...

Page 6: ...arcoal filters before use This product is intended for domestic use and the household environment only The product is not intended for an outside use or in a commercial setting Do not leave the product unattended during operation Brandt Asie Pte is not liable for damage caused by improper use or incorrect operation Determine which venting method is best for your application Vented non recirculatin...

Page 7: ...aces with a commercially available aluminum cleaner Abrasives and scouring agents can scratch stainless steel finishes and should not be used to clean finished surfaces cause irreparable damage appliance to function effectively regular maintenance is a must Clogged filters restrict airflow and may cause the motor to overheat Description of Parts 4 A Metal Air Outlet For recirculating mode AD9905B ...

Page 8: ...mes the low button light will keep shining the pairing mode is activated 4 Restart hood by turning off and on the power source The hood will beep 3 times 8 In order to disable to Auto Linkage System press and hold the low speed button for 8 seconds When the hood beeps once the Auto Linkage has been closed DUCTING VS RECIRCULATING MODE You can choose to install the hood as a ducting or recirculatin...

Page 9: ...ct low speed as normal usage Press once to select Medium Suction speed Press once to select High Suction speed Press and hold this button for 3 5s to activate the delay timer The cooker hood will operate for 15 minutes and then switch off automatically when activated Press once to select Booster P The hood will beep once and the light will turn blue flashing If using Auto Linkage mode press and ho...

Page 10: ...essionals Brandt Asie Pte Ltd is not liable for damages caused by improper handling and installation of the appliance 7 Installation Safety precautions Do not install the cooker hood where there are many doors or windows in order to avoid affecting the exhaust efficiency of the hood caused by air flow Install the cooker hood right above the hob The recommended distance between the hob and the lowe...

Page 11: ... onto the support screws Fully tighten the support screws Adjust screws Vr to level the hood body 8 DUCTING MODE 1 Wall drilling and bracket fixing Secure the sides of the brackets using 4 screws ST5X40 and screws wall plug 8x40 supplied 2 Fix the cooker hood and Upper Bottom chimney in the wall with screws Secure the sides of the brackets using the 2screws M4X10 supplied Inner ductcover Inner duc...

Page 12: ...ling and metal air outlet fixing secure the sides of the brackets using the 4 screws ST5 X 40 and the wall plug screws 8x40 supplied 2 Hook the hood body onto the support screws adjust the height and then connect the aluminum foil flue Pls refer RECIRCULATING MODE to picture Fig 1 ...

Reviews: