INSTALLATION INSTRUCTIONS
appropriate length).
B.
Connect the RED wire of the power harness
and camera harness to an Ignition
controlled power source (it is recommended
to trim cable to appropriate length).
C. The single BLACK wire is a negative 500ma
output, that will activate for 10 seconds when
the CA6 is triggered.(This can only be used to
trigger a interface or monitor.
Must use a relay
for higher current draw or a positive output.)
4) Programming:
(It is important that the device be programmed
in the vehicle on a flat surface with NOTHING
in front of the vehicle for a minimum of 4 feet).
A
- Slide power switch on Buzzer to Hi
position
B
- Aim sensor about 5 to 10 degrees higher
than horizontal
C
- Turn Ignition switch to Run position
(System will emit a series of beeps)
D
- Place box on either 3” or 4” side, depending
on how high curbs are in your local area at
a distance of
12” from the front of the
vehicle.
If
the
box
does
not
trigger
the
system
at
that
distance,
keep
moving
it
closer
until
the
system
alerts
you.
E
- Rotate sensor down until it is pointing at the
top edge of the front of the box (the sensor
has a pencil
beam IR line of sight and so it
must be aimed properly).
F
- Press the Program switch and the unit will
beep 2 times followed by a constant tone (if
this did not
happen return to step E and
possibly aim sensor slightly lower then
repeat step F).
G
- Raise box straight up and as soon as the
sensor no longer detects the box the solid
tone will stop
(this will confirm that the
sensor is aimed properly. If the sensor
continues to emit a tone with the box
lifted the sensor is aimed too low and is
picking up the road, if so repeat steps E & F
and retry step G).
H
- If the distance is acceptable and the height
is accurate then simply turn Ignition switch
Off and the
distance will now be
programmed in (if you prefer a different
distance then place the box at the desired
distance and redo all steps starting with step
D).
5) Pre-delivery testing:
A.
Tighten sensor to screw using supplied
Allen wrench to insure that the sensor will
not move during normal operation.
B.
Place box in front of vehicle at a distance of
30”
C.
Turn Ignition On (unit will beep to confirm
power up)
D.
Slide box toward vehicle until 3 beeps are
heard from Buzzer.
E. The CA6 single BLACK will show ground
and activate the interface or monitor.
F.
Measure distance from box to vehicle and
the distance and height should be as they
were when
programmed.
•
6) Use, Care and Maintenance:
A.
When the vehicle is turned ON you will
5000-CA6 rev2 Instructions 3-1-19
Page 3 of 5