1. Introduction 

The DXD/LTC option is available for both DXD models, the DXD16 and the DXD-8. 

This firmware can generate 2 separate streams of time code simultaneously at different formats. Each stream can be set as a 
Time Of Day time code generator or as a simple Run/Stop/Cue generator locked to the currently selected reference. 

The DXD/LTC transmits SMPTE 2059-2 "Synchronization Metadata" Management Messages on any PTP port where the SMPTE 
ST2059 Profile has been enabled. 

2. Installation 

Before using the DXD/LTC, be sure to update your DXD unit with the latest firmware, available on the Brainstorm website. The 
DXD/LTC will not operate with firmware older than 2.10. 

When you purchased the DXD/LTC option, you received a unique authorization key, a series of 4 numbers, separated by 
periods. This key is only valid for the model and serial number used when you placed the order. 

Enter this key in the FEATURE KEYS menu (10.5 on the DXD-8 and 11.5 on the DXD-16), under the main UTILITY menu. On the 
DXD-8, be sure to enter it in the TIME CODE line. 

After entering the authorization key, a message will ask you to confirm setting the feature key now, followed by another 
message confirming that the feature key has been set. This authorization procedure only needs to happen once, even with 
subsequent firmware updates. Keep that key handy in case you accidentally change it in the Feature Key menu.  

Once the Feature Key has been properly entered, several new menus will become accessible such as the TIME CODE menus. 
Other menus will also be affected. 

3. BNC Outputs Menus 

3.1 SIGNAL 

The BNC Outputs menus have a new choice for SIGNAL: Time Code. 

3.2 SOURCE 

After selecting Time Code as the type of signal for this group of outputs, either of the 2 Time 
Code Generators can be selected: TCG1 or TCG2 

3.3 RISE/FALL TIME 

Choices are available for the output waveform with rise and fall times ranging from 1µsec (square wave) to 50µsec (EBU). 

The default value is 40 µsec (SMPTE). 

NOTE 

On the DXD-16, 2 balanced outputs are available on the DB-25 connector (see appendix C), regardless of how the BNC 
outputs are configured. The BNC connectors can be used for unbalanced signal when additional outputs are required. 

On the DXD-8, only unbalanced BNC outputs are available. 

Summary of Contents for DXD

Page 1: ...Clocks Operations manual Version 2 10 January 2021 All materials herein Brainstorm Electronics Inc Brainstorm Electronics reserves the right to change or modify the contents of this manual at any time...

Page 2: ...1 4 4 2 1 1 OPERATING MODE 4 4 2 1 3 COLOR FRAMING 5 4 2 1 4 STOP HOLD FRAMES 5 4 2 2 TCG 1 OPERATIONS MENU 8 2 2 5 4 2 2 1 MOTION COMMAND 5 4 2 2 2 CUE POINT 5 4 3 TC Generator 2 menu 8 3 5 5 GPIO DX...

Page 3: ...sure to enter it in the TIME CODE line After entering the authorization key a message will ask you to con fi rm setting the feature key now followed by another message con fi rming that the feature ke...

Page 4: ...4 25 or 30 ND time code there will be no correction as each second is divided in a whole number of frames However that is not the case with 29 97 Even when using Drop Frame i e skipping 2 frames on ev...

Page 5: ...can be controlled different ways Via the TIME DATE Main Rotation Page GPIO or menu 8 2 2 The choices for MOTION COMMAND are Press ENTER to RUN Press ENTER to STOP Press ENTER to CUE for Simple Run Sto...

Page 6: ...me 229 97 NDF 29ND Non Drop 30 DF 30DF Dropped Frame 30 NDF 30ND Non Drop 7 Outputs Display Main Rotation When selecting a TCG in one of the BNC Outputs menus it will be shown on the OUTPUTS page of t...

Page 7: ...shown on the illustration below the DB 25 connector provides 2 balanced time code outputs in addition to 3 General Purpose Inputs GPI and 4 General Purpose Outputs GPO Time Code outputs are only avai...

Reviews: