background image

DXD/LTC User Manual (rev 2.10) 

Page 5

4.2.1.3 COLOR FRAMING 

Color Framing can only be enabled for PAL and NTSC formats, i.e. when the Rate/Count is set to: 

•25/25 
•29.97/DF 
•29.97/NDF 

Enabling Color Framing means that the color field sequence of the time code will be aligned with the PTP epoch (midnight on 
Jan 1, 1970) per ST2059. The color field sequence can have a duration a 4 or 8 fields (2 or 4 frames). 

4.2.1.4 STOP HOLD FRAMES 

This represents the number of consecutive frame periods during which the DXD will issue the stopped time code value ("freeze 
frame") whenever the generator stops or cues. 

This number varies from 1 to 99 or even CONTINUOUS. The default value is 10. 

4.2.2 TCG 1 OPERATIONS (MENU 8.2.2) 

4.2.2.1 MOTION COMMAND 

The Time Code Generator can be controlled different ways: Via the TIME & DATE Main 
Rotation Page, GPIO or menu 8.2.2. The choices for  MOTION COMMAND are: 

•Press ENTER to RUN 
•Press ENTER to STOP 
•Press ENTER to CUE (for Simple Run/Stop/Cue generator only). 

Simply select a command and hit the ENTER key. 

4.2.2.2 CUE POINT 

This menu is used to enter a CUE point to be used when the TCG is set to Simple Run/Stop/Cue. 

In that mode, using the CUE command will cause the TCG to return to the set CUE point. 

4.3  TC Generator 2 (menu 8.3) 

Menus 8.3 have the exact same functions as 8.2 but for the TCG 2. 

5. GPIO (DXD-16 only) 

New functions have been added to the DXD-16 GPIOs. 

5.1 GPIO INPUTS 

TCG 1 & 2 Run 
TCG 1 & 2 Stop 
TCG 1 & 2 Cue 

5.2 GPIO OUTPUTS 

TCG 1 Running 
TCG 2 Running 
Daily Jam Hold 
Daily Jam Pulse 

The CUE command (TGIO Input) only applies to the time code generator(s) set to Run/Stop/Cue, not Time-Of-Day. 

For detailed informations on the GPIO circuitry, please see the DXD-16 Owners Manual. 

Summary of Contents for DXD

Page 1: ...Clocks Operations manual Version 2 10 January 2021 All materials herein Brainstorm Electronics Inc Brainstorm Electronics reserves the right to change or modify the contents of this manual at any time...

Page 2: ...1 4 4 2 1 1 OPERATING MODE 4 4 2 1 3 COLOR FRAMING 5 4 2 1 4 STOP HOLD FRAMES 5 4 2 2 TCG 1 OPERATIONS MENU 8 2 2 5 4 2 2 1 MOTION COMMAND 5 4 2 2 2 CUE POINT 5 4 3 TC Generator 2 menu 8 3 5 5 GPIO DX...

Page 3: ...sure to enter it in the TIME CODE line After entering the authorization key a message will ask you to con fi rm setting the feature key now followed by another message con fi rming that the feature ke...

Page 4: ...4 25 or 30 ND time code there will be no correction as each second is divided in a whole number of frames However that is not the case with 29 97 Even when using Drop Frame i e skipping 2 frames on ev...

Page 5: ...can be controlled different ways Via the TIME DATE Main Rotation Page GPIO or menu 8 2 2 The choices for MOTION COMMAND are Press ENTER to RUN Press ENTER to STOP Press ENTER to CUE for Simple Run Sto...

Page 6: ...me 229 97 NDF 29ND Non Drop 30 DF 30DF Dropped Frame 30 NDF 30ND Non Drop 7 Outputs Display Main Rotation When selecting a TCG in one of the BNC Outputs menus it will be shown on the OUTPUTS page of t...

Page 7: ...shown on the illustration below the DB 25 connector provides 2 balanced time code outputs in addition to 3 General Purpose Inputs GPI and 4 General Purpose Outputs GPO Time Code outputs are only avai...