Braemar MCHV10D15 Owner'S Manual Download Page 12

OPERATION cont.

ERROR DISPLAY

Your High Wall air conditioner includes abnormal operation detection hardware
and software.  If the unit enters an abnormal state, the temperature indicator on
the fascia display will blink to display a corresponding error code.

Error codes and their meanings are shown below:

Note: if there are other error codes displayed, please contact Seeley qualified
service agents for details.

Please note the error code displayed when contacting Seeley service.

FAULT CONDITIONS
If the below conditions should occur, please turn off the air conditioner and
isolate its power immediately, and then contact the Seeley qualified service
agents for assistance.

Power cord is overheating or damaged.
Abnormal sound during operation.
Circuit breaker is continually tripping.
Burning smell is noticed.
Indoor unit is leaking condensate

·

·

·

·

·

Error Description

Defrost status entered. This is a normal occurrence in
HEAT mode.

Please contact Seeley qualified service agents.

Please contact Seeley qualified service agents.

Please contact Seeley qualified service agents.

It can be reset by restarting the unit.  If not, please contact
Seeley qualified service agents.

DRED mode 1 (full shut down), mode 2 (50% power) or
Mode 3 (75% power) signal received from Power Grid

Error Code

Heating icon ON 10s,

OFF 0.5s

F1

F2

C5

H6

d1, d2, d3

10

MAINTENANCE & SERVICE

SAFETY

AIR FILTER

Always isolate power for the air
conditioner from electricity mains
before cleaning or maintenance.

It is important to check and clean the
air filter as per the Maintenance
Schedule. A dirty air filter will not allow
the correct amount of clean air to pass
through your air conditioner, resulting
in poor performance and increased
running costs. Please follow the below
steps:-

1. Pull the front panel out and up from
the bottom as shown.

2. Remove the air filter and clean with
a vacuum cleaner. If it is very dirty,
wash with mild soapy water (below
45°C) and wipe off. Dry in the shade.

3. Make sure it is completely dry
before refitting it. You should never
operate the air conditioner without the
air filter in place.

INDOOR COIL (REFER PAGE 2)

OUTDOOR UNIT

REFRIGERANT

PLEASE REFER TO THE NEXT
PAGE FOR THE MAINTENANCE
SCHEDULE

Ensure drain connections are checked
on an annual basis (as set out in the
Maintenance Schedule below). Drains
can become blocked by all types of
insects, and rats have been known to
chew through the drain to get to the
water in the pipe.

The Outdoor unit has either one or two
fans, it draws air through the appliance
to expel the heat generated during the
cooling cycle. We recommend
checking that plants haven't grown into
or around the air intake or outlet, along
with other debris that may build up
over time, namely, leaves and the like.

A lack of refrigerant, due to a leak, will
cause the compressor to overheat and
expire prematurely. You will notice a
decline in cooling effect and an
increase in power consumption.
Therefore, having a qualified, licensed
technician service your air conditioner
will save you money in the long term.

(REFER PAGE 2)

Indoor
display

Error code (example only)

MSHV

Series High Wall Inverter Unit

D1S

SEELEY INTERNATIONAL –

OWNER

S MANUAL

11

Summary of Contents for MCHV10D15

Page 1: ...OWNER S MANUAL HIGH WALL INVERTER English MSHVD1S SERIES ...

Page 2: ...ioner Further it is also a condition of warranty cover that the Maintenance Schedule in the Manual is filled out by signing and dating it in the places indicated when the item is completed For complete warranty terms refer to the separate Warranty Booklet sold with the product Alternatively visit to download the terms Warranty terms are subject to property access and industry safety standards www ...

Page 3: ...6 TURBO 6 LIGHT 6 QUIET 7 TIMER SETTINGS 7 SWING UP DOWN LEFT RIGHT 7 I FEEL 8 SLEEP 8 9 LOCK FUNCTION 9 FAHRENHEIT CENTIGRADE 9 ENERGY SAVING 9 8 C HEATING FUNCTION 9 ERROR DISPLAY 10 MAINTENANCE SERVICE 11 MAINTENANCE SCHEDULE 12 OPERATION TIPS 13 TROUBLESHOOTING 14 WARRANTY SERVICE 15 6 or SEELEY INTERNATIONAL OWNER S MANUAL 1 CONTENTS ...

Page 4: ...lay panel 8 Remote control 9 Condensate tube 10 Gas Pipe 11 Liquid Pipe NOTE Display panel style or position may differ from the above graphics 1 2 3 4 5 6 8 7 9 10 11 Air outlet Air inlet 2 heating indicator temp indicator cooling indicator power indicator receiver window drying indicator MSHV Series High Wall Inverter Unit D1S ...

Page 5: ...agram on page 2 to ensure grass leaf and other matter are not drawn into or onto the Inlet side of the Outdoor unit Restriction to the air flow across the coil will reduce the system s capacity and result in high operation pressures and excessive operating costs IMPORTANT THE AUSTRALIAN GREENHOUSE OFFICE HAS ISSUED VARIOUS REGULATIONS ON THE USE AND DISPOSAL OF REFRIGERANTS IN THE UNIT FAILURE TO ...

Page 6: ...ontroller 1 Ensure there are no obstructions between the High Wall receiver and remote controller 2 Don t let the remote control drop onto hard surfaces or be subjected to sudden shocks in any way The warranty does not cover misuse or accidental damage 3 Don t place the remote control in direct sunlight or near extremes of temperature This will affect the control s temperature reading 4 Don t plac...

Page 7: ...AT modes depending on ambient temperature COOL Mode refrigerated cooling DRY mode for extracting moisture from the air FAN mode Fan only operation no cooling HEAT mode reverse cycle heating OPERATION cont SEELEY INTERNATIONAL OWNER S MANUAL 5 Signal transmitter ON OFF button I FEEL button TIMER ON OFF buttons buttons TURBO button SWING L R button SWING UP DOWN button LIGHT button QUIET button MODE...

Page 8: ...tdoor ambient temperature when equipped TEMP Note remote controller will always display the SET temperature BUTTONS Use to adjust the SET temperature within the range 16 30 C 61 86 F Hold the button down for quick adjustment Note TEMP adjustment is unavailable in AUTO mode The X FAN function can be used to continue operation of the indoor fan for an additional 10 minutes after the power is turned ...

Page 9: ...or buttons to adjust the clock time for the unit to start Holding these buttons will produce rapid adjustment When complete press the TIMER ON button again to set Pressing the TIMER ON button again will CANCEL the TIMER ON function TIMER OFF TIMER OFF cont controller display Use the or buttons to adjust the clock time for the unit to stop Holding these buttons down will produce rapid adjustment Wh...

Page 10: ... 16 23 C SET temperature will increase by 1 C every hour for 3 hours then stay constant until 7 hours SLEEP 2 SLEEP cont has elapsed It will then be decreased by 1 C then will continue to run at this temperature b If SET between 24 27 C SET temperature will increase by 1 C every hour for 2 hours then stay constant until 7 hours has elapsed It will then be decreased by 1 C then will continue to run...

Page 11: ...thout adjusting the settings Review mode will be quit if no button is pressed within 10 seconds or if the ON OFF MODE TIMER or SLEEP buttons are pressed SLEEP 3 OPERATION cont SEELEY INTERNATIONAL OWNER S MANUAL 9 LOCK The remote controller can be locked from inadvertent button operation Press both or buttons simultaneously to lock or unlock the remote controller The icon will be displayed and wil...

Page 12: ...ately and then contact the Seeley qualified service agents for assistance Power cord is overheating or damaged Abnormal sound during operation Circuit breaker is continually tripping Burning smell is noticed Indoor unit is leaking condensate Error Description Defrost status entered This is a normal occurrence in HEAT mode Please contact Seeley qualified service agents Please contact Seeley qualifi...

Page 13: ...E 2 OUTDOOR UNIT REFRIGERANT PLEASE REFER TO THE NEXT PAGE FOR THE MAINTENANCE SCHEDULE Ensure drain connections are checked on an annual basis as set out in the Maintenance Schedule below Drains can become blocked by all types of insects and rats have been known to chew through the drain to get to the water in the pipe The Outdoor unit has either one or two fans it draws air through the appliance...

Page 14: ... refrigerant charge Check refrigeration connections for soundness Check outdoor fans Check electrical connections Check overall installation Report to the home owner user all tasks that require attention Please NOTE the Maintenance Schedule covers Year 1 to Year 5 To preserve your investment for many years afterwards we strongly recommend that you continue to maintain and service the Braemar High ...

Page 15: ... cold contraction of the plastic parts in the Unit when the temperature is changing This is a normal condition when the air conditioner has not been used for a long time or during first use of the Unit This is caused by the Indoor unit giving off smells permeated from building material from furniture or smoke for example if someone is cooking food When indoor air temperature reaches the setting on...

Page 16: ...ion any plastic parts may expand or shrink due to a sudden temperature change in this event a clicking sound may occur 5 1 Unit is operating in AUTO mode 5 2 The required SET temperature is outside of the allowable range 6 1 DRED Demand Response energy saving mode has been activated by the Electricity Supplier 1 1 Wait for power to resume 1 2 Replace the fuse or reset the breaker 1 3 Check thermos...

Page 17: ...26 477 NOTE Seeley International strives for continuous product improvements therefore specifications are subject to change without notice Unit colour may vary slightly from that depicted in this booklet Installation and commissioning of this system to the manufacturer s specification and compliance with industry standards and local state and national regulatory codes are the responsibility of the...

Page 18: ...16 MSHV Series High Wall Inverter Unit D1S NOTES ...

Page 19: ...SEELEY INTERNATIONAL OWNER S MANUAL 17 NOTES cont ...

Page 20: ...0 526 477 seeleyinternational com It is the policy of Seeley International to introduce continuous product improvements Accordingly specifications are subject to change without notice Please consult with your dealer to confirm the specifications of the model selected 66129917002 ...