OPERATION cont.
I FEEL
Press the I FEEL button to activate this
feature. The remote controller will act
as the temperature thermostat,
sending a temperature reading to the
unit every 10 minutes. By this method,
the unit will react to where the remote
controller is positioned. I FEEL will be
shown on the remote controller
display.
Press the I FEEL button again to
this feature.
Press SLEEP button to toggle between
the SLEEP modes and cancel, as
described below. Default setting is
SLEEP mode
‘
OFF
’
:-
In COOL and DRY modes,
after running for one hour, the main
unit SET temperature will increase by
1°C, then after 2 hours will increase by
2°C, then will continue to run at this
temperature.
cancel
SLEEP
SLEEP 1:
In HEAT mode, the SET temperature
will decrease by 1°C and then 2°C for
the first 2 hours, and then stay
constant.
In COOL mode, the SET
temperature will vary according to the
below scenarios:-
a) If SET temperature starts between
16-23°C, SET temperature will
increase by 1°C every hour for 3
hours, then stay constant until 7 hours
SLEEP 2:
SLEEP cont.
has elapsed. It will then be decreased
by 1°C, then will continue to run at this
temperature.
b) If SET between 24-27°C, SET
temperature will increase by 1°C every
hour for 2 hours, then stay constant
until 7 hours has elapsed. It will then
be decreased by 1°C, then will
continue to run at this temperature.
c) If SET between 28-29°C, SET
temperature will increase by 1°C for 1
hour, then stay constant until 7 hours
has elapsed. It will then be decreased
by 1°C, then will continue to run at this
temperature.
d) If SET at 30°C, SET temperature
will stay constant until 7 hours has
elapsed. It will then be decreased by
1°C, then will continue to run at this
temperature.
In HEAT mode:-
a) If SET at 16°C, it will remain at this
temperature.
b) If SET between 17-20°C, SET
temperature will decrease by 1°C for 1
hour, then will continue to run at this
temperature.
c) If SET between 21-27°C, SET
temperature will decrease by 1°C for 2
hours, then will continue to run at this
temperature.
SLEEP cont.
d) If SET between 28-30°C, SET
temperature will decrease by 1°C for 3
hours, then will continue to run at this
temperature.
this is a User programmable
curve, created as follows:-
a) When in SLEEP 3 mode, hold the
TURBO button down until the remote
displays
‘
1 hour
’
and the SET
temperature will display.
b) Adjust the SET temperature, then
press TURBO button to confirm.
c) The remote display will move to the
next time setting (
’
2 hours
’
,
‘
3 hours
’
or
‘
8 hours
’
), and the SET temperature
can agin be programmed.
d) Repeat until the
‘
8 hours
’
SET
temperature has been entered. Once
completed, the remote display will
show the original settings.
The SLEEP 3 settings will be stored
and can be reviewed at any time in the
SLEEP 3 mode by pressing the
TURBO button and scrolling through
without adjusting the settings.
Review mode will be quit if no button is
pressed within 10 seconds, or if the
ON/OFF, MODE, TIMER or SLEEP
buttons are pressed.
SLEEP 3:
8
OPERATION cont.
SEELEY INTERNATIONAL –
OWNER
’
S MANUAL
9
LOCK
The remote controller can be locked
from inadvertent button operation.
Press both
▲
▼
▼
or
buttons
simultaneously to lock (or unlock) the
remote controller. The
icon will be
displayed, and will flicker when a
button is pressed.
The temperature display can be
toggled between Centigrade and
Fahrenheit scales by pressing the
MODE and
buttons simultaneously.
FAHRENHEIT / CENTIGRADE
ENERGY SAVING
When in COOL mode, press the TEMP
and CLOCK buttons simultaneously to
start Energy Saving function. The
remote controller display will show the
‘
SE
’
icon. Repeat to cancel.
When in HEAT mode, press the TEMP
and CLOCK buttons simultaneously to
start 8°C Heating function. The
remote display will show
and a
selected temperature of
‘
8°C
’
(46°F).
Repeat to cancel.
8°C HEATING FUNCTION
MSHV
Series High Wall Inverter Unit
D1S