Mounting 

Bracket

Top Cover

Bottom 

Cover

Mounting 

Bracket

Supply 

Knockouts

X 8

X 8

A

Remove top and bottom covers. 

B

Measure from top of unit to tip of showerhead. 
Subtract 2" and add the total to the desired 
mounting height (see page 2). Mark the wall 
with level horizontal line. 

A

Position Bracket on top of shower and secure 
to wall with 1/4" screws (provided by installer).

B

Position Slip Ring on top of shower against 
ceiling and secure to wall with 1/4" screws 
(provided by installer).

C

Position Shroud and secure to lower bracket with 
screws provided. Using holes on top of shroud 
as guides, drill and tap #10-24 holes in Slip Ring. 
Secure Shroud to Slip Ring.

D

Connect water supply to copper tubes inside the 
shower unit. Turn on water to your shower and 
check for leaks. Attach top and bottom covers.

C

Drill 1/4" holes on marked line and attach 
mounting brackets to wall using suitable hardware.  
Hang unit on brackets. Fasten to wall at the four 
anchor holes, using suitable hardware.

1

Install Shower

Supplies may be brought in from 
back of shower unit or through 
knock- outs located on top of 
shower unit.

Installing Optional Vertical Shroud

(mm)

Ceiling

Slip Ring

Shroud

Slots for 1/4" 

Dia. Screws 

(supplied by 

installer)

10-24 x 1/2" 
Allen Button 

Head Screws

1" (25)

4" (102)

6-1/2" 

(165)

6-1/2" 

(165)

Bracket

Top of 

Wall Saver 

Shower

Summary of Contents for WS-3WMT

Page 1: ...s from packaging and make sure all parts are accounted for before discarding packaging material If any parts are missing do not begin installation until you obtain the missing parts Make sure that all water supply lines have been flushed and then completely turned off before beginning installation Debris in supply lines can cause valves to malfunction Product warranties may be found under Products...

Page 2: ...kets OPTIONAL 3 4 union Dimensions mm Rough in supply lines before making connections Use the Cold Inlet for Tempered Supply C L Recommended Shower Height from Showerhead tip to finished floor Age Male Female Adult 6 0 1 83m 5 6 1 68m Teen 6 0 1 83m 5 6 1 68m Pre Teen 5 6 1 68m 5 6 1 68m Distance to finished floor 2 51 Mounting Bracket Mounting Bracket Supply from Wall Anchor Holes Anchor Holes 11...

Page 3: ... to lower bracket with screws provided Using holes on top of shroud as guides drill and tap 10 24 holes in Slip Ring Secure Shroud to Slip Ring D Connect water supply to copper tubes inside the shower unit Turn on water to your shower and check for leaks Attach top and bottom covers C Drill 1 4 holes on marked line and attach mounting brackets to wall using suitable hardware Hang unit on brackets ...

Page 4: ...polish in accordance with the manufactures instructions Many of these products leave a protective coating that helps prevent future smears and fingerprints Grease and Oil To remove grease and oil use a quality commercial detergent or caustic cleaner Apply in accordance to the manufactures instructions and in the direction of the polish lines Precautions Avoid prolonged contact with chlorides bleac...

Reviews: