5
Valve and tubing connections
Flush supply lines before making connections.
Do not apply pipe sealant to compression fittings.
A
Connect tube from sprayhead to valve
assembly. The male connector for the valve
assembly will remain tight and leakproof
when tubing is cut and installed properly.
B
Using a sharp razor, cut tubing squarely and
remove any burrs. Do not pinch or crush end
of tubing.
C
Loosen nut on fitting. Moisten end of tube
and push into fitting until it is firmly seated.
Tighten nut to secure tube to fitting (make
sure nut it securely tightened). If connector
leaks, reseat tubing according to above
procedure. If leaking persists call your
Bradley representative for assistance.
D
Hang valve assembly on pedestal bracket.
Use screws provided to hang valve on
bracket.
E
Attach flexible hosing to thermostatic mixing
valve, two places.
F
Connect hoses to the stop valves. Make sure
the hot supply is connected to the hot inlet on
the valve (marked with the letter "H") and the
cold supply is connected to the cold inlet on
the valve (marked with the letter "C").
Volume Control
Valve
Bracket
Flexible
Hose
Stop
Valve
Thermostatic Mixing
Valve Assembly
(S45-2504)
3/8" Dia. Tube
from Sprayhead
(R68-600014)
Tubing
Male Tube
Connector
Nut
Valve Mounting Bracket
Valve Mounting Screws
Valve Bracket
3/8" Dia. Tube
from Sprayhead