background image

12

Express® Lavatory System SS-Series
SS-2/IR/STD, SS-2/IR/JUV

Installation - Obsolete

4/24/08

Bradley Corporation • 215-1243 Rev. E; EN 08-805

Cleaning and Maintenance Instructions

IMPORTANT: Strong alkaline or acid-based chemicals and cleansers should not be
used to clean Terreon®. If these chemicals come in contact with the Terreon® surface,
wipe off the surface immediately and flush with soapy water.

Terreon® and panel maintenance

The bowl and sprayhead cover are constructed of Terreon®, a densified solid surface material
composed of an acrylic modified polyester resin. Terreon® is resistant to chemicals, stains, burns
and impact. Surface damage can be easily repaired with everyday cleaners or fine grit abrasives.
The panel and sprayhead body are made of an acrylic/ABS laminate, and will not chip, peel or flake.
With regular cleaning, your Terreon® fixture will provide years of dependable service.

Cleaning

• Daily Cleaning:

Wipe the surface with a damp cloth and wipe dry.

• Weekly Cleaning:

Wipe the surface with a damp cloth and a household liquid detergent.

Stubborn stains can be removed as follows:

1. Using a #7448 Scotch-Brite® pad, scrub with an abrasive cleanser such as Ajax®,

Comet® or Soft Scrub® and water.

2. Clean thoroughly with soapy water and allow to dry.

• Scorch Marks:

Although Terreon® will not burn, a lit cigarette in contact with Terreon®

could leave a scorch mark. Scorch marks can be removed by buffing with a #7448 Scotch-
Brite pad or with an abrasive cleaner. 

Repair kit:

In the unlikely event your Terreon® surface becomes damaged, it can easily and

inexpensively be repaired. Contact your Bradley representative to order a repair kit and be
sure to specify color when ordering.

Panel cleaning

IMPORTANT:  Do not use abrasive cleansers to clean the panel or sprayhead body.
Abrasive cleaners can mar the surface.

Graffiti/Vandalism:

If vandals create markings on the panel, Bradley recommends using

Motsenbocker’s LIFT OFF® to remove ink and spray paint. Remover #3 is for ink and markers,
and Remover #4 is for spray paint. Motsenbocker’s LIFT OFF® can be ordered through
Sanitary Maintenance Service Inc. (call 1-800-451-5523 x 425 or visit
www.santitarymaintenance.com/product.htm  for ordering information). After cleaning with
LIFT OFF®, give the panel a final thorough cleaning with a liquid tub and tile cleaner to
remove soil and maintain the glossy finish.

NOTE: Use of brand names is intended only to indicate a type of cleaner. This does not constitute an
endorsement, nor does the omission of any brand name cleaner imply its inadequacy. Many products
named are regional in distribution and can be found in local supermarkets, department and hardware
stores or through your cleaning service. It is emphasized that all products should be used in strict
accordance with package instructions.

Summary of Contents for SS-2/IR/JUV

Page 1: ...m SS Series Standard and Juvenile Height Express Lavatory Systems are ADA compliant Table of Contents Pre Installation Information 2 Dimensions 3 4 Installation Instructions 5 11 Cleaning and Maintena...

Page 2: ...A compliant juvenile height mounting The SS 2 IR JUV Express Lavatory System is compliant with Americans with Disabilities Act ADA Accessibility Guidelines for Buildings and Facilities Building Elemen...

Page 3: ...solete SS 2 IR STD SS 2 IR JUV Bradley Corporation 215 1243 Rev E EN 08 805 4 24 08 8 203 22 559 34 864 6 152 50 1270 8 1 2 216 21 533 10 254 Radius 8 203 Radius 30 762 38 1 4 971 SS 2 IR STD Express...

Page 4: ...IR STD SS 2 IR JUV Installation Obsolete 4 24 08 Bradley Corporation 215 1243 Rev E EN 08 805 38 965 34 864 29 737 11 279 9 229 6 152 4 102 30 762 25 635 11 279 9 229 6 152 4 102 34 864 Standard Heigh...

Page 5: ...tandard Height Express only 1 Rough in 1 2 NPT hot and cold supply lines through wall at dimensions shown 2 Rough in 1 1 2 NPT drain waste connection through wall at dimensions shown MM 32 813 28 5 8...

Page 6: ...MINIMUM PULL OUT RATING OF 1 000 LBS 23 1 2 597 9 3 8 238 2 3 4 70 13 1 2 343 1 25 23 1 2 597 9 3 8 238 3 76 1 2 NPT HOT AND COLD SUPPLIES OR TEMPERED SUPPLY STUB OUT 2 50 FROM WALL FINISHED FLOOR CE...

Page 7: ...stall the 110 volt GFCI electrical outlet per local code at the location shown in Figure 2 4 Install 6 3 8 wall anchors with a minimum pull out rating of 1 000 lbs supplied by installer at the locatio...

Page 8: ...ounted the Standard and Juvenile Height frames should rest on the floor IMPORTANT Anchoring the frame to a wall that is not flat may cause the frame to bend If necessary install shims to compensate fo...

Page 9: ...2 Attach the front of the bowl assembly to the frame using the two 1 4 20 x 3 8 pan head screws and washers Do not tighten screws at this time IMPORTANT When bolting the bowl assembly to the frame and...

Page 10: ...e solenoid valves with the flexible supply hose see Figure 6b 2 Install the drain plug in the hole in the bottom of the bowl see Figure 7 3 Beneath the bowl install the 1 4 rubber washer onto the drai...

Page 11: ...lenoid tube connectors by loosening the compression nut and firmly pushing the tubing into the tube connector until the tubes are fully seated then re tighten the compression nut hand tight and then t...

Page 12: ...ot burn a lit cigarette in contact with Terreon could leave a scorch mark Scorch marks can be removed by buffing with a 7448 Scotch Brite pad or with an abrasive cleaner Repair kit In the unlikely eve...

Page 13: ...ptic soaps require no dilution 1 Using two screwdrivers or similar tool push up on the release tabs located beneath each soap dispenser and pull out the soap tanks from the sprayhead see Figure 9a 2 T...

Page 14: ...intenance program IMPORTANT Do not use abrasive cleansers to clean the soap tank Abrasive cleaners can mar the surface Clean exterior Use warm water and soap to clean the exterior of the soap dispense...

Page 15: ...L Juvenile 186 1160 GRAY Juvenile 186 1160A PUTTY Juvenile 186 1160B COAL 12 TORX HEAD PANEL SCREW 160 378 GRAY 160 378A PUTTY 160 378B COAL Assembly of Components Paneling SCUFF PANEL 185 030 GRAY 18...

Page 16: ...noids and sensors Remove the eight Phillips head screws located in the bottom of the sprayhead body and lift the cover shelf off To re install sprayhead cover shelf Position the cover shelf on the spr...

Page 17: ...from the valve body Be careful not to lose the armature or spring 2 Remove the diaphragm Remove any particles that have been trapped between the diaphragm and the valve seat Rinse off the diaphragm an...

Page 18: ...18 Express Lavatory System SS Series SS 2 IR STD SS 2 IR JUV Installation Obsolete 4 24 08 Bradley Corporation 215 1243 Rev E EN 08 805...