Step 5: Completing installation
1. Turn on the water supply to the Express® and check for leaks.
2. Pass your hand in front of each station’s sensor until all the air is purged from the lines and
water is flowing smoothly.
3. ACTIVATION RANGE ADJUSTMENT
NOTE: Complete only if range adjustment is required.
NOTE: The range is factory preset at approximately six inches.
To adjust the activation range, follow the procedure outlined below:
• Open the box cover per Step 3, procedure #4, found on page 9 (see Figure 6a).
• Locate the activation adjustment potentiometer (see Figure 6b, page 9).
IMPORTANT: The maximum rotation is only 3/4 of a turn.
NOTE: The label on the activation adjustment indicates the direction to increase (+) and decrease
(-) the range.
• Make the adjustment with a small slotted screwdriver.
• Set the range to “minimum” (-).
• Remove all objects from the basin
• Reset the sensor by removing one battery, waiting ten seconds and then reinstalling the
battery.
• Slowly turn the adjustment to increase (+) the activation range. If the sensor activates, back
the adjustment off by 1/8 turn.
• Once the range is adjusted, reset the sensor again by removing one battery, waiting ten seconds
and then reinstalling the battery.
• Wait five seconds for the sensor to adapt, then test the range. If the range is okay, then
replace the valve box cover and tighten the screws.
4. After testing is complete, reinstall panel to frame. Fasten panel with seven Torx-head screws
provided (see Figure 3 on page 7).
NOTE: For Express® units with optional soap dispensers, see pages 13 and 14 for soap dispenser
maintenance instructions.