LC840 

Installation

6

 

10/24/08

 Bradley 

Corporation

 • 215-1599 Rev. B; EN  07-1004C

6

Push Button Flush Valve

7

Countertop

Terreon

®

 Top:

  Set the lavatory 

top in place so the back and wall 
sides are flush with the edge of the 
cabinet. Do not secure the top with 
silicone caulk at this time. The top 
will be secured after installation is 
complete and the unit is tested for 
leaks.

Laminate Top:

 Reattach the top 

with screws originally provided 
when unit was shipped.

A

8

Faucet, Optional Foot Valve and Supplies

Before connecting supplies, install the 
faucet per manufacturer's instructions.

Connect one end of the 
supply hose to the supply 
shank on the faucet.

Connect the other end of the 
hose to the foot valve outlet 
connection.

A

Connect the hot and cold 
water supply piping to the 
1/2" NPT inlet connections 
on the foot valve.

B

Connect the P-trap to the sink’s 
1-1/4" or 1-1/2" O.D. drain pipe 
and to the 1-1/2" O.D. tailpiece 
from the wall.

IMPORTANT: Laminate top 
option requires 1-1/4" to 1-1/2" 
adapter for drain connection.

C

Turn on the water supplies 
and check for leaks and 
adequate water fl ow. 
Activate the faucet, 
bedpan washer and fl ush 
valve seeral times to purge 
air from the supply lines.

D

To access the fl ush 
valve, remove the 
seat back cushion.

Connect the flush valve water 
supply piping (supplied by 
installer) to the flush valve’s 
1" NPT inlet.

A

Insert the tube from the “O” outlet 
on the flush valve casting to the 
“O” on the flush button housing.

Insert the tube from the “L” outlet 
on the flush valve casting to the 
“L” on the flush button housing.

B

Summary of Contents for LC840

Page 1: ...et U S Patent Nos 6 643 865 and 7 007 318 Table of Contents Pre Installation Information 2 Supplies Required 2 Step 1 Rough Ins 3 Step 2a Wall Mount Water Closet 3 Step 2b Floor Mount Water Closet 3 S...

Page 2: ...llation manual to ensure proper installation When finished with the installation file this manual with the owner or maintenance department Compliance and conformity to local codes and ordinances is th...

Page 3: ...ovided D If the floor concrete is lightweight or less than 4 thick Bradley recommends through bolting to steel angles under the floor hardware by installer Using a 5 8 concrete drill bit and the water...

Page 4: ...PT bedpan washer hose C Shim and level cabinet as necessary C Remove the floor template from the unit A Not applicable to rigid bedpan washer option ref Step 5B For more details please reference the r...

Page 5: ...section of the inlet pipe coming from to the bedpan washer inlet pipe may be trimmed if necessary A Connect the inlet pipe to the compression fit elbow B Secure the inlet pipe to the bracket with the...

Page 6: ...f the hose to the foot valve outlet connection A Connect the hot and cold water supply piping to the 1 2 NPT inlet connections on the foot valve B Connect the P trap to the sink s 1 1 4 or 1 1 2 O D d...

Page 7: ...ticularly under corrosive conditions is essential Always start with the simplest solution and work your way toward the more complicated Routine Cleaning Daily or as often as needed use a solution of w...

Reviews: