6
Bradley Corporation • 215-781 Rev. D; EN 03-310
Barrier-Free Column Shower
HN-400
Installation Instructions
12-16-2003
Installation Instructions for Type O HN-400 Column Shower
Step 1: Install column shower components
NOTE: Flush supply lines before making connections.
1. Remove the five bolts that secure the disposable washer to
the drain and lift the washer off.
2. Bolt the shower to the drain with the five bolts (removed in
procedure #1) and oval washers provided (see Figure 7).
3. Loosen the screw(s) securing the shower’s cover and lift the
cover off. DO NOT remove the screw(s)!
Step 2: Connect water supply
1. Drop the supplies to the top of the column shower.
2. Slide the column cover up the vent and supply piping.
NOTE: If you are installing a column shroud, slide the slip ring
up the vent and supply piping first, and then slide the column
cover up (see page 7 for shroud installation).
3. Make the supply connections. The supply connection must be
made inside the top of the shower so that there is no interference with the piping and the column
cover.
4. Turn water to the shower on and test for leaks and adequate water flow.
5. Secure the column cover with the screws provided.
NOTE: For column shower drains with a dome grate, install the two halves of the grate with the
screws provided after the column installation is complete.
(5) 5/16"-18
HEX-HEAD
BOLTS
160-092
(5) WASHERS
142-034
Figure 7
Figure 8
Supplies from Above/Vent Off Line