background image

 Menu Functions                           

Gain

Adjusts the Gain from -3dB to +18dB in 3dB steps.

Red Gain

Requires White Balance to be set to Manual

Blue Gain

Requires White Balance to be set to Manual

Detail

Adjusts the detail level from 0 to 15.  Normal setting is around 5.

Shutter Speed

Adjusts the shutter speed from 1/2sec to 1/10,000 sec.

White Balance

Includes BARS if available

Gamma

There are 3 levels of gamma available.  

Master Pedestal

Not available for the BE_HD10

Output Standard

SD or HD in 8 different standards

Iris Range

Set to 18 for BE_HD10 or 255 for broadcast lenses

Pan Speed

High or Low

Tilt Speed

High or Low

Reverse Pan/Tilt

Cycles through the 4 direction combinations

Zoom Reverse

Reverses the direction of the zoom control

Focus Reverse

Reverses the direction of the focus control

Head Select

Selects control of another remote head 1-99

Change Head ID

Re-assigns the ID of the current head

Reset ALL to #1

Re-sets all connected heads to ID #1

Infra Red Mode

Toggles the IR mode on or Off

Power Up Memory

Set/Clear.  This  feature  can  only  be  used  with  a 

Protocol  Converter

.

Setting the memory will store the current Zoom and Focus positions in
the 

Protocol Converter

 and reset them every time it powers up.  

Store Position

Stores the current position head and camera as a preset position 1-99

Go To Position

Recalls the previously set positions 1-99

Digital Zoom

Digital Zoom On/Off

Remote Relay

Commands a remote relay On/Off

Auto Focus

Auto Focus On/Off

Zoom Limit

Sets the current zoom position as the zoom in limit. 

 Zeroing the controls                       

Should the Pan, Tilt or Zoom controls appear to be off-centre (sometimes this will induce drift) the
controls can be electrically re-centred.

Whilst the AUX LED is flashing at power-up, push the AUX button.

 Specifications                                  

Power:  

12v,  200mA

Dimensions: 

W.165mm, D.90mm, H.35mm

Output:

RS485 or RS232c

Max Cable Length:

1km

 (with RS485 device or 

protocol converter)

David Bradley Engineering Ltd - www.bradeng.com