43
TROUBLESHOOTING
LED
Status
Control
Status
Probable
Cause
None
(LED
not
on
or
flashing)
Electrical
power
not
present.
Control
power
switch
in
“OFF”
position.Supply
voltage
interuppted.
One
short
flash
every
four
seconds
Stand
‐
by
mode,
Thermostat
is
satisfied
(no
faults).
Temperature
demand
is
satisfied
(no
call
for
heat).
Alternates
bright
and
dim
(Heartbeat)
Thermostat
calling
for
heat
(no
fault).
Tank
temperature
below
set
point
of
thermostat.
Short
flash
once
every
second
Weak
pilot
signal
on
last
call
for
heat.
1.
Unstable
pilot.
2.
Pilot
tube
block
or
restricted.
3.
Oxidation
build
up
on
pilot
electrode.
4.
Wire
damage
to
pilot
assembly
or
bad
connection
at
gas
valve.
Short
flash
once
every
two
seconds
Idle
remote
command
off
1.
Control
put
in
idle
or
Sabbath
mode
from
accessory
module
Two
flashes,
three
second
pause
Pressure
switch
not
working
‐
closed
position.
1.
Pressure
switch
tubing
kinked
or
blocked.
2.
Blocked
pressure
tap
on
switch.
3.
Faulty
pressure
switch.
Three
flashes,
three
second
pause
Pressure
switch
or
blower
temperature
switch
not
working
‐
open
position.
1.
Vent
blockage
or
improper
vent
configuration.
2.
Pressure
switch
tubing
kinked
or
blocked.
3.
Blower
not
spinning
up
to
speed.
4.
Vent
temperature
too
high
5.
Faulty
pressure
switch
or
vent
limit
switch.
Four
flashes,
three
second
pause
Excessive
tank
temperature.
System
must
be
reset.
1.
Excessive
sediment
2.
Hot
water
entering
the
tank
from
another
source
in
the
potable
loop.
3.
Faulty
gas
valve.
Five
flashes,
three
second
pause
False
pilot
flame
present.
1.
Pilot
valve
stuck
in
open
position.
Six
flashes
‐
one
flash,
three
second
pause
(Soft
lockout)
Failed
to
light
pilot.
System
auto
resets
after
5
minutes.
1.
Unstable
pilot.
2.
Pilot
tube
blocked
or
restricted.
3.
Oxidation
build
up
on
pilot
electrode.
4.
Wire
damage
to
pilot
assembly
or
bad
connection
at
gas
valve.