background image

 

13

WATER CONNECTIONS 

 

Note:

  BEFORE PROCEEDING WITH THE INSTALLATION, CLOSE THE 

MAIN WATER SUPPLY VALVE. 

After shutting off the main water supply, open a faucet to relieve the water line 
pressure to prevent any water from leaking out of the pipes while making the 
water connections to the water heater.  After the pressure has been relieved, 
close the faucet.  The COLD water inlet and HOT water outlet are identified on 
the top of the water heater.  The fittings at the cold water inlet and hot water 
outlet are dielectric waterway fittings with 3/4” NPT male thread.  Make the 
proper plumbing connections between the water heater and the plumbing 
system to the house.  Install a shut-off valve in the cold water supply line. 

 
If this water heater is installed in a closed water supply system, such as the 
one having a back-flow preventer in the cold water supply, provisions shall be 
made to control thermal expansion.  

DO NOT

 operate this water heater in a 

closed system without provisions for controlling thermal expansion.  Your 
water supplier or local plumbing inspector should be contacted on how to 
control this situation 

 

After installation of the water lines, open the main water supply valve and fill 
the water heater.  While the water heater is filling, open several hot water 
faucets to allow air to escape from the water system.  When a steady stream 
of water flows through the faucets, close them and check all water 
connections for possible leaks.

  NEVER OPERATE THE WATER HEATER 

WITHOUT FIRST BEING CERTAIN IT IS FILLED WITH WATER.

 

 

WARNING

 

FAILURE TO INSTALL AND MAINTAIN A NEW, LISTED 3/4” X 3/4” 
TEMPERATURE AND PRESSURE RELIEF VALVE WILL RELEASE THE 
MANUFACTURER FROM ANY CLAIM, WHICH MIGHT RESULT FROM 
EXCESSIVE TEMPERATURE AND PRESSURES.

 

 

CAUTION

 

If sweat fittings are to be use, 

DO NOT

 apply heat to the nipples on top of 

the water heater.  Sweat the tubing to the adapter before fitting the adapter 
to the water connections.  It is imperative that heat is not applied to the 
nipples containing a plastic liner.

 

Summary of Contents for GAS-FIRED WATER HEATER

Page 1: ...reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier For your family s comfort safety and convenience...

Page 2: ...vent of improper usage or storage of gasoline or other flammable materials in the location where the water heater is installed the technology will resist ignition of the flammable vapors outside the c...

Page 3: ...on Air Supply 11 Water Connections 13 Gas Connections 16 GENERAL OPERATION 17 Lighting and Shutdown Instructions 18 Thermostat Adjustment 19 Burner Flame Check 20 MAINTENANCE 21 INSTALLATION DRAWING F...

Page 4: ...e to comply with these instructions This water heater is not design certified for installation in a mobile home Such an installation may create a hazardous condition and will nullify the warranty This...

Page 5: ...on gas control A sacrificial anode is used to extend tank life The removal of this anode for any reason will nullify the warranty In areas where water is unusually active an odor may occur at the hot...

Page 6: ...ible to gas and water supply lines DO NOT locate the water heater where water lines could be subjected to freezing temperatures Make sure the cold water pipes are not located directly above the gas co...

Page 7: ...ith little or no odor to reveal their presence NOTE DAMAGE TO THE WATER HEATER CAUSED BY EXPOSURE TO CORROSIVE VAPORS IS NOT COVERED BY THE WARRANTY DO NOT OPERATE THE WATER HEATER IF EXPOSURE HAS OR...

Page 8: ...e purchased from your plumbing professional The drain pan must be piped to an adequate drain The piping must be at least 3 4 inch 1 9 cm in diameter and pitched for proper drainage It is recommended t...

Page 9: ...it shall be installed on top of a metal or wood panel or equivalent extending beyond the full width and depth of the appliance by at least three 3 inches 7 6 cm in any direction or if the appliance is...

Page 10: ...system was previously sized for another gas appliance that has been removed the venting system may now be too large Refer to the latest edition of the National Fuel Gas Code ANSI Z223 1 latest editio...

Page 11: ...ers and flue tubes with possible damage to the water heater When an exhaust fan is installed in the same room with a heater sufficient openings for air must be provided in the walls Undersized opening...

Page 12: ...ottom of the enclosure All Air From Outdoors The confined space shall be provided with two permanent openings one commencing within 12 inches 31cm of the top and one commencing within 12 inches 31cm f...

Page 13: ...sion DO NOT operate this water heater in a closed system without provisions for controlling thermal expansion Your water supplier or local plumbing inspector should be contacted on how to control this...

Page 14: ...pressure relief valve into the opening provided and marked for this purpose on the water heater Note Some models may already be equipped or supplied with a combination temperature and pressure relief...

Page 15: ...mixing cold and hot water in branch supply lines Such valves are available from the manufacturer of this water heater or a local plumbing supplier Please consult with a plumbing professional WARNING H...

Page 16: ...dope has become lodged in the inlet screen of the gas valve Extreme care must be taken to ensure no pipe dope enters the gas valve Avoid excessive torque when tightening the gas supply line to the gas...

Page 17: ...sition 3 Shut off the gas supply to the water heater 4 Close the cold water supply shut off valve 5 Open the drain valve on the water heater by turning the knob counter clockwise The drain valve has t...

Page 18: ...s STOP Follow B in the 7 Look into sight 5 Remove outer on inner door igniter button to view pilot glass window 6 Locate piezo 9a FOR EXHIBIT A GAS CONTROLS Depress and hold down red pilot set button...

Page 19: ...dial until the minimum acceptable temperature is achieved See figure 2 above for approximate temperature settings 160 F Control 180 F Control Figure 3 The thermostat dial is set to its lowest temperat...

Page 20: ...nk becomes heated BURNER FLAME CHECKS Cast Iron Burner At the time of installation and at periodic intervals not more than 6 months a visual check of the main burner and pilot flames should be made to...

Page 21: ...s listed on the water heater 5 Annually remove the inner door and main burner assembly to clean orifices and related parts of any dirt or other foreign material Inspect the burner ports for obstructio...

Page 22: ...interval for inspection and replacement of the anode rod Contact the plumbing professional who installed the water heater or the manufacturer listed on the rating plate for anode replacement informat...

Page 23: ...___________ Supplier Supplier Phone No ____________________________________________ CAUTION FOR YOUR SAFETY DO NOT ATTEMPT REPAIR OF COMBINATION GAS CONTROL BURNERS OR GAS PIPING REFER REPAIRS TO A QU...

Page 24: ...24 INSTALLATION FOR POTABLE WATER Figure 5...

Page 25: ...25 PARTS LIST DRAWING...

Page 26: ...6 Flue Baffle Assembly 19 Gas Feedline to Burner 7 Dip Tube Cold Water Inlet 20 Gas Feedline to Pilot 8 Temperature and Pressure Relief Valve 21 Thermocouple Lead 9 Glass Lined Tank 22 Piezo Igniter L...

Page 27: ...or boiler treatment must not be introduced into potable water used for space heating 3 This water heater must not be connected to an existing heating system or component s previously used with a non p...

Page 28: ...28 NOTES...

Reviews: