8
Minimum Clearances
This installation must allow access to the front of the water heater and
adequate clearance must be provided for servicing and operating this water
heater. The water heater may be installed on either a combustible or non-
combustible floor. If the water heater is to be installed directly on carpeting, it
must be installed on top of a metal or wood panel extending beyond the full
width and depth of the appliance by at least 3 inches
(7.6 cm)
in any direction
or, if the appliance is to be installed in an alcove or closet, the entire floor must
be covered by the panel. The minimum clearances to combustibles for this
water heater are: 0 inch
from the sides and rear, 5 inches
(12.7 cm)
from the
front of the jacket, 0 inch from the vent connector and 15 inches
(38.1 cm)
from
the jacket top. Increase distances to provide clearance for servicing.
Venting
Figure 1 - Vent Terminal Clearances
WARNING
Failure to adhere to these installation and operating
instructions may create a hazard to life and property and will
nullify the warranty.
Summary of Contents for 238-45917-OON
Page 28: ...28 Wiring Diagram Figure 6 ...
Page 40: ...40 NOTES ...