Bradford White 100T399-SOLA Supplement To Installation & Operation Manual Download Page 5

TEMPERATURE ADJUSTMENT 

APPROXIMATE TIME/TEMPERATURE RELATIONSHIPS IN SCALDS 

120°F 

(49°C)

 

More than 5 minutes 

125°F 

(52°C)

 

1½ to 2 minutes 

130°F 

(54°C)

 

About 30 seconds 

135°F 

(57°C)

 

About 10 seconds 

140°F 

(60°C)

 

Less than 5 seconds 

145°F (

63°C

Less than 3 seconds 

150°F 

(66°C)

 

About 1½ seconds 

155°F 

(68°C)

 

About 1 second 

 

 

CAUTION

 

This water heater, when set at a lower temperature setting is not capable of producing hot water of sufficient 
temperature for sanitizing purposes.

 

This water heater is equipped with an energy cut out device to prevent overheating.  Should overheating occur or 
the gas supply fails to shut off, turn off the control panel power switch to the appliance and call a qualified service 
agency. 

 

NOTICE 

The lower the temperature setting, the greater the energy efficiency, both to heat the water and to maintain the 
storage temperature during standby periods.  Lower water temperatures also extend tank life.  Remember, no 
water heating system will provide exact temperatures at all times.  Allow a few days of operation at this setting to 
determine the correct temperature setting consistent with the requirements for the installation.  

 

 

 

The water heater temperature setting is adjusted by using the control display mounted to the control surround jacket of the 
water heater.  The water heater thermostat is set at the lowest setpoint of 70

(21

C)

 when shipped from the factory.  

The control display shows the temperature setpoint in degrees Fahrenheit 

(

F)

 or degrees 

Celsius (

C)

, and the status of 

the water heater (“Standby” or “Run”).   

 

For energy efficient operation of your water heater, the suggested initial temperature setting is 120

(49

C)

.  During the 

winter season, or any cold period, you may desire a higher temperature setting to adjust for the colder incoming water.  
This adjustment, however, may cause additional condensation to form on the cooler tank surface.  This does not mean 
the tank is leaking.  During summer months, the warmer incoming water temperatures will benefit the performance of your 
water heater and reduce the amount of condensation developed.   

 

Condensation does not mean your tank is leaking.  Most of reported tank leaks on installation are proven to be 
condensation.  To avoid unnecessary inconvenience and expense, make sure the tank is leaking before calling an 
independent servicing contractor or qualified service professional. 

 

If the water heater is to remain idle for 30 days or more or is subjected to freezing temperatures while shut off, the water 
heater and piping should be fully drained and the drain valve should be left fully open.  Refer to the “General Operation” 
section of this Installation and Operation Manual for the procedure on draining the water heater. 
 

 

DANGER

 

Hotter water increases the risk of scald injury.  Scalding may occur within 5 seconds at a temperature setting of 140°F 

(60°C).

  To protect against hot water injury, install an ASSE approved mixing valve in the water system.  This valve will 

reduce point of discharge temperature by mixing cold and hot water in branch water lines.  A licensed plumbing 
professional or local plumbing authority should be consulted. 

 

Summary of Contents for 100T399-SOLA

Page 1: ...not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas su...

Page 2: ...f the water heater provides for setting and displaying the temperature setpoint and monitoring the status of the water heater Durable direct spark ignition system The temperature adjustment range is 7...

Page 3: ...le that can have the power supply interrupted by a switch that is used to control lights or another appliance If wiring in conduit is required cut the line cord close to the control board and make the...

Page 4: ...rod sparks to the burner and gas valve opens burner ignition 5 Flame signal confirmed 6 Blower remains at reduced speed for a short time to stabilize flame 7 Blower increases to full speed for full i...

Page 5: ...it F or degrees Celsius C and the status of the water heater Standby or Run For energy efficient operation of your water heater the suggested initial temperature setting is 120 F 49 C During the winte...

Page 6: ...highly recommended that the setpoint be adjusted to the lowest temperature possible for the needs of the installation Make sure the water heater control display is not in a public area that can resul...

Page 7: ...d Temperature Up button until desired setpoint temperature appears in the display Step 2 Press DONE button for new setting to take effect immediately If the DONE button is not pressed the new temperat...

Page 8: ...DONE button is not pressed the new temperature setting will take effect in approximately 10 seconds NOTICE Pressing the NEXT button instead of DONE will enter the display to show unused screens such a...

Page 9: ...between F or C Press DONE when selection is complete Display will revert back to DHW setpoint NOTICE Pressing the NEXT button instead of DONE will enter the display to show RMT for Remote Firing Cont...

Page 10: ...y indicating that the control cycled through the maximum number of ignition retries for ignition The control will make another 4 ignition attempts after the 15 minute waiting period 10 If the exhaust...

Page 11: ...c Mode for 12 5 minutes after the last button press for viewing unless Done button is pressed to exit Diagnostic Mode Step 2 The display will show the flame sense current in microamps when the burner...

Page 12: ...xt button and the display will show the temperature sensor reading Step 6 Press lower right Next button and the display will show the manual firing rate adjustment This function is not currently used...

Page 13: ...ons Check to make sure the wiring connections on the control module from terminals J4 10 and J8 2 are connected together 62 Fan speed not proved Check the PWM wire harness connection from the blower t...

Page 14: ...reattempt ignition after 15 minute waiting period Check gas valve wiring and gas valve operation during the ignition cycle If burner lights but quickly goes out check the flame sensor wire or the flam...

Page 15: ...11592 11308 11032 10763 10502 10248 10000 9760 9526 80 9299 9078 8862 8653 8449 8250 8057 7869 7685 7507 90 7333 7165 7000 6839 6683 6531 6383 6238 6098 5961 100 5827 5697 5570 5446 5326 5208 5094 49...

Page 16: ...16 Condensate Trap Elbow 17 Silicone hose 18 Outer Door Service Panel Specify model 19 Clip 20 NSF Escutcheon 21 Exhaust Pressure Switch 22 Nuts 23 Collector Limit Switch 24 Screw 6 32 x 3 8 25 Clean...

Page 17: ...ition Specify model 3A Burner Ass y Specify model 16A Screw 8 32 x 1 4 RHCR 4A Blower Specify model 17A Gasket Flame Sensor 5A Silicone Hose 18A Flame Sensor 6A Burner Mounting Insert Gasket 19A Trans...

Page 18: ...s pending Current Canadian Patents 2 092 105 2 107 012 2 108 186 2 112 515 2 143 031 2 239 007 2 262 174 2 314 845 2 409 271 2 476 685 2 504 824 2 548 958 CC Ignition Control Assembly 1C Control Mount...

Page 19: ...19 NOTES...

Page 20: ...20 NOTES...