7
GB
P
1 - LOCATION
Install the unit on an internal wall (fig. 2) in
a position which is suitable for correct mea-
surement of the room temperature, avoiding
installation in niches, behind doors or cur-
tains, or near heat sources.
2 - INSTALLATION
Open the unit by pressing button P (fig. 3)
while at the same time pulling in the direc-
tion of the arrows.
Remove the terminal covers(fig. 4). To
fasten the base to a rectangular recessed
box (fig. 5) use the 2 screws provided.
To install the base in a round box (fig. 6) use
the provided spacer.
To fix the base to the wall (fig. 7) use the
spacer and the two screws with inserts, all
provided.
WARNING. For the unit to work properly, we
recommend you install it on a flat surface,
being careful not to overtighten screws.
WIRING
Wiring will depend on the type of equipment
controlled by the thermostat: refer, therefo-
re, to the diagram in fig. 8 or fig. 9. Refit the
terminal cover.
KEY
Mains power supply wires
L = phase
OK
Fig. 3
Fig. 4
Fig. 5
Fig. 2
TH125_ITF 24081800 01_07 15-01-2007 16:23 Pagina 7