BPS YZ102 IOM-R1.0  Page 7 of 14

© 2018 - Best Purging Systems Corporation

Unit Tubing Instructions

1.  Carefully read “Protected Enclosure Criteria” on page 3 

and “Enclosure Connection Requirements” on page 4 

before proceeding.

2.  The following instructions are for Units mounted external 

to the Protected Enclosure. Consult factory for units 

which are mounted inside or through the face of the 

Protected Enclosure.

3.  Connect 1” Protective Gas Supply Header to Unit Supply 

Connection using 1/4” .035 welded or seamless wall 

stainless steel, fully reamed tubing. Protective Gas 

Supply tubing should not exceed 15 feet length and 5 

bends.

4.  Connect Unit Enclosure Supply Connection to the 

Enclosure Supply bulkhead fitting using 1/4” .035 welded 

or seamless wall stainless steel, fully reamed tubing. 

Enclosure Supply tubing should not exceed 5 feet in 

length and 5 bends.

5. 

MULTIPLE  ENCLOSURE  CONNECTIONS  ONLY. 

Connect Multiple Enclosure Protective Gas Supply Piping 

(3/4” rigid pipe, fully reamed) from Protected Enclosure 

#1 to Protected Enclosure #2. Repeat procedure for 

connection between Protected Enclosure #2 and #3. 

Protective Gas Supply piping should not exceed 10 feet 

length and 5 bends between each enclosure.

6.  Connect Unit Enclosure Reference Connection to the 

Enclosure  Reference  bulkhead  fitting  using  1/4”  .035 

welded or seamless wall stainless steel, fully reamed 

tubing. Enclosure Reference tubing should not exceed 

20 feet length and 5 bends.

Unit Mounting Instructions

1.  Carefully read “Protected Enclosure Criteria” on page 3 

and “Enclosure Connection Requirements” on page 4 

before proceeding.

2. 

Determine the Mounting configuration for the purge unit. 

See “Typical Mounting Configurations.”

3. 

Firmly secure the unit mounting flange, if utilized, to the 

unit face plate using the hardware provided.

4.  Drill and ream four mounting holes in the protected 

enclosure.  (see  page  6  for  unit  mounting  flange 

dimensions and unit layout)

5.  Based on “Enclosure Connection Requirements” on page 

4, drill and ream a 29/64” hole in protected enclosure, 

install  1/4”  Enclosure  Supply  Bulkhead  fitting.  NOTE: 

Protected Enclosure Supply should be installed at 

extreme opposite corner from part # PV-2 Purge Vent 

and 8” from the Enclosure Reference Connection.

6.  Next, drill and ream a 29/64” hole in protected enclosure, 

install 1/4” Enclosure Reference Bulkhead fitting. NOTE: 

Protected Enclosure Reference should be installed at 

least 8” from the Enclosure Supply Connection.

7.  Install PV-2 Purge Vent at extreme opposite corner from 

the Enclosure Supply Connection. 

(WARNING: The PV-2 

Purge Vent is gravity operated and MUST be mounted 

in a true vertical position.)

8.  Install the PV-2 Purge Vent Mounting Hub through a 

1-1/4” hole on the Protected Enclosure.

9.  Secure the Purge Vent from inside the Protected 

Enclosure using the Purge Vent Mounting Nut.

10. Secure Purge Unit Mounting Flange to protected 

enclosure using hardware provided.

Mounting Set Up

Enclosure Warning Label (EWL) 

MUST

 be permanently affixed on or near all protected enclosure doors, entries and openings.

Enclosure Warning Label(s)

Frame/Panel Mount

Bottom Mount

Top Mount

Left Mount

Right Mount

Typical Mounting Configurations

WARNING NOTICE

THIS ENCLOSURE CONTAINS HOT COMPONENTS

ENCLOSURE SHALL NOT BE OPENED UNLESS AREA IS KNOWN TO BE FREE 

OF 

FLAMMABLE  MATERIALS 

OR 

UNLESS

 A

LL 

DEVICES  HAVE  BEEN 

DE-ENERGIZED FOR THE TIME SPECIFIED BELOW

.

MINIMUM COOLONG TIME:

WARNING - PRESSURIZED ENCLOSURE

ENCLOSURE SHALL NOT BE OPENED UNLESS AREA IS KNOWN TO BE FREE 

OF 

FLAMMABLE  MATERIALS 

OR 

UNLESS

 A

LL 

DEVICES  HAVE  BEEN 

DE-ENERGIZED. P OWER 

SHALL 

NOT  BE  RESTORED A FTER 

ENCLOSURE 

HAS  BEEN O PENED 

UNTIL

 C

OMBUSTIBLE 

DUSTS  HAVE  BEEN  REMOVED 

AND ENCLOSURE HAS BEEN PURGED AND PRESSURIZED IN ACCORDANCE 

WITH THE UNIT START UP INSTRUCTIONS.

AREA CLASSIFICATION

PRESSURIZATION TYPE

TEMPERATURE CODE

BEST PURGING SYSTEMS CORPORATION     WWW.PURGEIT.COM 

LA MARQUE, TEXAS USA

BEST PURGING SYSTEMS CORPORATION     WWW.PURGEIT.COM 

LA MARQUE, TEXAS USA

Summary of Contents for YZ102

Page 1: ...ual BPS YZ102 IOM R1 0 9 18 Copyright 2018 Best Purging Systems Corporation All Rights Reserved Model YZ102 CI W or B V With Pressure Switch shown w Mounting Flange Model YZ102 CI W or B H With Pressure Switch shown w Mounting Flange Model YZ102 CI L U Less Pressure Switch shown w Mounting Flange ...

Page 2: ...NOT intended for dilution applications Please consult factory for more information A copy of this manual must be read and retained by the operator of this unit User s agent s are responsible for transferring this manual to the user prior to installation and start up This unit must be installed and operated per this manual The Authority Having Jurisdiction should be advised before installation of t...

Page 3: ...fying Your Unit Major Components List Filter Regulator Enclosure Pressure Valve Purge Valve Purge Press Indicator Enclosure Press Indicator Optional Pressure Loss Alarm Enclosure Warning Label EWL 1 General Information All electrical connections of the protected enclosure and purge unit must be performed by trained and knowledgeable personnel In addition all connections must be installed in accord...

Page 4: ...e 5 Multiple Protected Enclosures must be purged in series and should be connected from the smallest to the largest enclosure 6 Enclosure Supply connections between multiple enclosures must be at least the diameter of the Purge vent exhaust 3 4 1 Protective Gas Supply Header Purge Unit Unit Supply 1 4 Tubing Protected Enclosure Purge Vent Model PV 2 Enclosure Supply 1 4 Tubing Enclosure Reference ...

Page 5: ...rol Valve Venturi Orifice Model YZ102 CI L U Universal Mount Less Pressure Switch Rear View Model YZ102 CI W or B V Vertical Mount With Pressure Switch Rear View Typical Pneumatic Flow Diagram Denotes Customer Supplied Tubing Required Purge Vent Enclosure Pressure Gauge Optional EXP Pressure Switch Purge Injection Pressure Gauge Enclosure Warning Label Protected Enclosure Enclosure Supply Enclosur...

Page 6: ...nt Purge Vent 2 5 6 5 Model YZ102 CI W or B Side View C L 4 3 5 Model YZ102 CI W or B Mounting Flange YZ102 CI L U Side View C L 4 1 75 12 Universal Mounting Flange Model YZ102 CI W or B V Front View Model YZ102 CI L U Front View 12 11 5 11 5 12 0 25 Typ 8 0 5 6 6 12 11 5 15 75 0 5 16 25 8 125 0 25 Typ 6 15 75 8 125 11 11 5 0 5 16 25 0 25 Typ 6 0 625 12 4 0 3 375 0 25 Typ 8 11 375 10 3125 1 6875 0...

Page 7: ...nting flange dimensions and unit layout 5 Based on Enclosure Connection Requirements on page 4 drill and ream a 29 64 hole in protected enclosure install 1 4 Enclosure Supply Bulkhead fitting NOTE Protected Enclosure Supply should be installed at extreme opposite corner from part PV 2 Purge Vent and 8 from the Enclosure Reference Connection 6 Next drill and ream a 29 64 hole in protected enclosure...

Page 8: ...um 60 psi reading on Purge Injection Pressure Gauge adjust regulator if required 8 Close Purge Control Valve fully The Enclosure Pressure Indicator should return to a Safe 0 25 w c reading 9 Calculate total protected enclosure volume when empty Determine Purge Time required 5 minutes minimum Required Exchange Time Enclosure Volume 4 Volumes 1 minute per 1 0 cf 5 Volumes 1 minute per 0 8 cf 10 Mark...

Page 9: ...o off scale to the high side this is normal 6 Confirm a Min 60 psi on Purge Injection Pressure Gauge 7 Allow unit to purge protected enclosure for the required time marked on the Unit Start Up Instructions 5 minutes minimum Required Exchange Time Enclosure Volume 4 Volumes 1 minute per 1 0 cf 5 Volumes 1 minute per 0 8 cf 8 Upon completion of the required purge time close the Purge Control Valve f...

Page 10: ... to Twenty Four 24 Months after date of shipment Regardless of registration the Commencement Date for either warranty period shall be the date of BEST Factory shipment or under prior special written agreement at time of Product purchase no greater than Ninety 90 Days after the BEST Factory shipment date WARRANTY EXTENSIONS An extended warranty shall extend the effective warranty based on the terms...

Page 11: ... repair shipping damage or any other reason Please note that shipping damage must be claimed promptly with the carrier and is the responsibility of the recipient To procure an RMA number please contact Best Purging Systems Customer Service at 1 844 PURGE IT 787 4348 A Best Purging Systems Customer Service Associate will then work with you to resolve any problems with the Unit if at all possible an...

Page 12: ...onal Electrical Code NEC ANSI NFPA 70 2017 edition Standard for Purged And Pressurized Enclosures for Electrical Equipment ANSI NFPA 496 2017 edition Recommended Practice for the Classification of Flammable Liquids Gasses or Vapors and of Hazardous Classified Locations for Electrical Installations in Chemical Process Areas NFPA 497 2017 edition ANSI American National Standards Institute 11 West St...

Page 13: ...BPS YZ102 IOM R1 0 Page 13 of 14 2018 Best Purging Systems Corporation Maintenance Service Notes ...

Page 14: ...____ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ Unit Identification Information Date of Installation __________________...

Reviews:

Related manuals for YZ102