Introduction
To assist you through the installation and operation of your enclosure pressurization unit, Best Purging Systems has provided the
following information boxes throughout this manual. This information is intended to clarify certain differences between the model styles
and configurations of this unit and to warn the user and installer of potential dangers due to improper installation or operation.
Important Manual Information Designators
IMPORTANT NOTE
WARNING
HELPFUL HINT
Technical Description
Model YZ102
is a Type Y or Z purge unit designed to protect
electrical equipment in Class I hazardous locations. Type Z
applications reduce the hazardous location rating inside the
enclosure from Division 2/ Zone 2 to non hazardous. This
allows general purpose equipment to operate in Division 2/
Zone 2 areas. Type Y applications reduce the hazardous
location rating inside the enclosure from Division 1/ Zone 1 to
Division 2/ Zone 2. This allows Division 2/ Zone 2 equipment
to operate in Division 1/ Zone 1 areas.
Model PV-2
spark arresting Purge Vent MUST be installed
on the protected enclosure.
This unit is designed to meet or exceed NEC - NFPA 70, NFPA
496, EN 50016 and IEC 60079-02 requirements.
Operating this unit without a Model PV-2 Purge
Vent may cause harm, death or dismemberment to
personnel and can cause damage to instrumentation.
This unit is NOT intended for dilution applications.
Please consult factory for more information.
A copy of this manual must be read and retained by the
operator of this unit. User’s agent’s are responsible for
transferring this manual to the user prior to installation and
start up.
This unit must be installed and operated per this manual.
The Authority Having Jurisdiction should be advised
before installation of this unit. This manual DOES NOT
supersede any national, local or plant codes.
All specifications are subject to change without notice.
IMPORTANT NOTE
Page 2 Introduction
Technical Description
Important Notes
Important Manual Information Designators
Page 3 Identifying Your Unit
Model Number Designations
General Information
Unit Specifications
Material Specifications
Protected Enclosure Criteria
Major Components List
Page 4 Getting Starting
Pressurization Unit & Enclosure Connection
Requirements
Single Enclosure Connections
Multiple Enclosure Connections
Page 5 Unit Layout
Unit Layout & Component Description
Typical Pneumatic Flow Diagram
Page 6 Mounting & Installation
Universal, Vertical & Horizontal Mount Purge
Unit & Purge Vent Dimensions
Page 7 Mounting Set Up
Unit Mounting Instructions
Unit Tubing Instructions
Enclosure Warning Label(s)
Page 8 Pressurization Unit & Switch Set Up
Pressurization Unit Set Up
Pressure Switch Set Up
Typical Pressure Switch Wiring Diagram
Page 9 Pressurization Unit Operation
Cross Ventilation Diagram
Page 10 Warranty & Liability Statements
Page 11 Factory Repair & Service Guide
Page 12 Reference Information
Page 13 Maintenance & Service Notes
Page 14 Unit Identification Information
Table of Contents