Figure 3
Figure 4
Step 5 Carefully lift the fixture up and into position over
the ceiling mounting bracket. The bracket contains two
1/4-20 screws that protrude downward. Align the screws
from the ceiling mounting bracket with the holes in the
fixture’s canopy and reinforcement plates. Secure into
position with lock washers and nuts.
Step 6 Once the fixture is mounted securely into position
make the electrical connections. Make wire connections
using twist-on connectors: connect the black fixture wire
to the hot supply wire (typically black); connect the white
fixture wire to the neutral supply wire (typically white);
connect the copper fixture wire to the ground wire or
ground terminal at the outlet box, push field wiring con-
nections into the junction box. (See Figures 2 and 3)
Step 7 With connections made and wiring tucked into the
junction box, carefully lift the canopy cover up and into
position and secure into place with the decorative knob
and threaded nipple.
Step 8 If installing in an area exposed to moisture or
weather apply weather proof caulking or silicon type adhe-
sive to the perimeter of the canopy at the ceiling to pre-
vent moisture from entering between fixture canopy and
the ceiling.
Step 9 Install lamps per label recommendations, lamps can
be installed by reaching up through the bottom of the fix-
ture.
Step 10 Install glass diffuser panels into the housing.
Position the diffuser so that the ribbed portion of the
glass faces outward. The diffuser can be lifted into posi-
tion behind upper retainer bracket and then lowered into
channel bracket on the bottom. Install the lower diffuser
through the opening in the bottom of the housing and ori-
ent into position. (See Figure 4)
Step 11 Restore power to circuit and confirm proper
installation.