BOWIE PUMPS Eco-Seal Series Installation, Operation And Maintenance Manual Download Page 7

 

ES IOM Rev 1 

-

 5/13/2021

 

 

7

 

NOTICE:

 

Both Pressure Relief locking caps come 

with a control marker listing the existing 

pressure setting.  Removal of the control 

marker will void all warranty of BPOC 

products.  

 

BI

-

DIRECTIONAL PRESSURE RELIEF PLATE SETTING

 

The Bi

-

Directional Pressure Relief Plate pressure setting should be set a minimum of 20

-

30 psi higher than 

the operating pressure.  When adjusting the pressure setting, the correct locking cap must be adjusted for 
the correct direction of flow at operating rotational speed of the pump

s drive shaft.  Pressure may be ad-

justed within a range of approximately 20 psi per spring.  Additional springs are available for higher psi 
changes.  Contact your BPOC repair or warranty agent for more information.

 

 

Adjusting the PRESSURE SETTING:

 

1.

 

To INCREASE the pressure setting

, remove the correct locking cap (see selecting the correct locking 

cap).  Loosen the locking nut, and then rotate the setting screw clockwise.  Record the difference 
between original and new settings.  Tighten the locking nut, and replace the locking cap.

 

2.

 

To DECREASE the pressure setting

, remove the correct locking cap (see selecting the correct lock-

ing cap).  Loosen the locking nut, and then rotate the setting screw counterclockwise.  Record the 
difference between original and new settings.  Tighten the locking nut, and replace the locking cap.

 

 

 

Selecting the CORRECT LOCKING CAP viewing the front plate of the pump:

 

To adjust

 

flow pressure for CLOCKWISE shaft rotation

 

a)

 

The drive shaft below the idler shaft.  Adjustments must be made to the 

RIGHT side spring

.

 

b)

 

The drive shaft above the idler shaft.  Adjustments must be made to the 

LEFT side spring

.

 

 

To adjust

 

flow pressure for COUNTERCLOCKWISE shaft rotation

 

a)

 

The drive shaft below the idler shaft.  Adjustments must be made to the 

LEFT side spring

.

 

b)

 

The drive shaft above the idler shaft.  Adjustments must be made to the 

RIGHT side spring

.

 

 

NOTICE:

 

Adjustment of pressure settings by any 

party other than a specified BPOC repair or 

warranty agent will void all warranty of 

BPOC products. 

 

NOTICE:

 

 

Any internal pump relief valve is designed to protect the pump from excessive pressure and 

must NOT be used as a system pressure control valve.  See your local Bowie dealer for a list 

of Bowie manufactured system pressure control valves.

 

BI

-

DIRECTIONAL PRESSURE RELIEF PLATE

 

 

An available bi

-

directional pressure relief plate is manufactured and can be supplied by Bowie Pumps of 

Canada Ltd.  This will set a different maximum pressure for each direction of fluid flow.  Initial pressure is 
set at the factory to the customer

s specifications, based on the specific operational rotational speed of the 

pump

s drive shaft.

 

BI

-

DIRECTIONAL PRESSURE RELIEF PLATE OPERATION

 

Pressure Relief locking caps are 

exposed to and retain some 

pumped fluids 

 

Summary of Contents for Eco-Seal Series

Page 1: ...e system MUST conform to all applicable local and national regulations and safety standards This manual is intended to assist in the in stallation and operation of the Bowie Eco Seal Series pumps and when possible kept with the pump Pump service shall be performed by quali fied technicians ONLY Service shall con form to all applicable local and national reg ulations and safety standards Thoroughly...

Page 2: ...ringent environmental and safety standards There are three lines of Eco Seal Series pumps 300 Eco Seal the standard pump 300 Eco Seal S short drive neck for ac cess in tight spaces 300 Eco Seal ED extended duty PUMP DIMENSIONS EXPLODED VIEWS AND OTHER TECHNICAL INFORMATION All technical information including pump dimensional diagrams exploded views with part listings and other technical informatio...

Page 3: ... lines and piping MUST be free of all leaks NOTICE Bowie pumps must be installed only in systems design by qualified engineering personnel Bowie pumps should only be installed in duties for which Bowie Pumps of Canada Ltd have specified the attributes of the pump System design must conform to all applicable regulations and codes and provide warning of all system hazards NOTICE PTO and hydraulicall...

Page 4: ...ng a surging vibration to the fluid system POWER TAKE OFF PTO DRIVE Bowie pumps may be driven by a PTO drive A direct drive shaft with a universal joint on each end of the shaft is used to connect the pump to the drive A sleeve joint can be used to compensate for any play caused by road conditions General guidelines for proper pump drive 1 The angle of drive shaft between pump and PTO must be NO L...

Page 5: ...ge line and reading the pressure gauge This pressure must be a minimum of 20 30 psi 1 4 2 1 Bar higher than the maximum system operating pressure or pressure relief plate setting and must not exceed 150 psi DO NOT operate the pump against a closed discharge valve for more than 15 seconds If adjustments need to be made refer to the Relief Valve Setting and Adjustment sec tion of this manual NOTICE ...

Page 6: ...ons with sticky fluids that solidify within the pump i e waxes adhesives etc use a fluid that prevents solidification of the fluid to facilitate flushing NOTICE Properly dispose of all waste fluids in ac cordance with appropriate codes and regu lations PUMP OPERATION Disconnecting fluid or pressure containment components dur ing pump operation can cause serious personal injury death or major prope...

Page 7: ...ngs Tighten the locking nut and replace the locking cap Selecting the CORRECT LOCKING CAP viewing the front plate of the pump To adjust flow pressure for CLOCKWISE shaft rotation a The drive shaft below the idler shaft Adjustments must be made to the RIGHT side spring b The drive shaft above the idler shaft Adjustments must be made to the LEFT side spring To adjust flow pressure for COUNTERCLOCKWI...

Page 8: ...s of grease applied approximately every four 4 operating hours in the front drive neck of the pump For all other grease fitting locations we recommend 1 2 ounces of grease applied every four 4 operating hours The actual amount of grease to be applied can be identified as the point when high re sistance to further greasing has been achieved For operating conditions above those specified refer to th...

Page 9: ...ore For storage longer than 6 months in addition to following the short term storage steps the following pro cedures should be carried out every 2 3 weeks 1 Rotate the pump several full revolutions to avoid the gears setting in the housing 2 If corrosion is present apply light oil to all rotating parts and repeat step 1 PREVENTATIVE MAINTENANCE Failure to set vehicle emergency brake and chock whee...

Page 10: ... or toxic fluids pump must be flushed before service PUMP DISASSEMBLY 1 Remove the two drain plugs 3318 from back plate 2 Remove the three end plugs 4308BF from the front and back plates 3 Remove secure wire from packing nut and packing nut itself 4301 4 Remove the quick change sleeve ECOEDSL and quick change containment seal 3325V from the Drive shaft 5 Remove all bolts on the back plate and remo...

Page 11: ...additional housing gasket on to hardened wear plate 10 Apply light oil on two seals and around the seal pockets in the back plate Insert one lip seal 3325 on to each of the two shafts ends Keep lips orientation toward the casing 11 Mount back plate with four bolts tightening in a cross pattern 12 Turn drive shaft to ensure proper meshing of gears and acceptable clearances between the gears and pla...

Page 12: ...ne Damaged or worn parts Pressure Relief Plate is set too low or attached incorrectly if installed Pump speed is too fast for viscosity or volatility of the liquid Pump not securely mounted Loose undersized piping and fittings Pump is too far from fluid source Improper drive or hydraulic connection Dry running the pump Excessive heat in the pump Excessive discharge pressure Cavitation Normal end o...

Page 13: ...ES IOM Rev 1 5 13 2021 13 CONTACT INFORMATION Bowie Pumps of Canada Ltd 9333 41 Ave T6E 6R5 Edmonton AB Tel 1 877 862 6943 Email info bowiepumps com ...

Reviews: