Bowens ESPRIT digital DX1000 Operating Instrctions Download Page 6

Esprit Digital Operating Instructions 

 

11 

MAIN CONTROLS & DISPLAY 

Refer to Fig.2.  The ‘FUNCTION’ button, the ‘UP’ 

 , ’DOWN’ 

 buttons and the three-digit 

display provide a simple means of setting and displaying the main functions.  Other buttons are 
used to access individual functions. 

The unit is designed to retain all settings indefinitely.  If for any reason the memorised settings 
become corrupted then default settings will be used instead. 

‘FUNCTION’ Button 

The ‘FUNCTION’ button is the main display control and selects the required function for display or 
adjustment.  Each press of the button selects the next available function as shown by the leftmost 
digit or digits.  The remaining digits show the value of the function. 

NOTE: Certain functions such as the IR Remote and Modelling have to be switched on before the 
‘FUNCTION’ button can access them.  When these are first selected the appropriate display will 
be automatically selected for checking or adjustment. 

If the ‘FUNCTION’ or ‘UP’/’DOWN’ buttons are not pressed within 4 seconds then the controls and 
display will automatically return to the default ‘FLASH’ function.  Use the ‘FUNCTION’ button to 
reselect if required. 

Functions likely to require less frequent adjustment are accessible via an ‘OPTIONS’ sub-menu.  
This allows the user to customise certain functions without complicating the main controls. 

Function Selection 

Momentarily press the ‘FUNCTION’ button to scroll through the available functions as follows: 

Display Range 

X.X  Description 

FX.X 

5.0 to 10 

Display Flash power value.  Use ‘UP’ or ’DOWN’ to adjust. 

LX.X 

5.0 to 10 

Display Lamp power value.  Use ‘UP’ or ’DOWN’ to adjust. 

CXX 

0 to 12 

Display IR Remote Channel.  Use ‘UP’ or ’DOWN’ to select. 

 

Option Selection 

Press and hold down the ‘FUNCTION’ button for approximately one second until the display 
changes to show one of the values below.  Release the button.  If the SOUNDER is on it will 
sound continuously while the ‘FUNCTION’ button is held down.  Now momentarily press the 
‘FUNCTION’ button to scroll through the options until the desired one is reached as follows: 

Display Range 

X.X  Description 

X.X.X 

0.0.0 to 9.9.9 

Firmware version. 

di.X 

1 to 9 

Display brightness value. Use ‘UP’ or ’DOWN’ to adjust. 

Fd.X 

0 or 1 

Flash dump 0 = OFF, 1 = ON. Use ‘UP’ or ’DOWN’ to select. 

In.X 

0 or 1 

Intermittent Lamp Operation 0 = NORMAL, 1 = PULSE MODE. 
Use ‘UP’ or ’DOWN’ to select. 

 

A more detailed explanation of these options is given in the OPTIONS section. 

FLASH DUMP Option 

The preferred mode for the ‘AUTO-DUMP’ function can be selected from the ‘OPTIONS’ sub-
menu as follows:  

Option Description 

Fd.0 

Flash dump off.  Always resistively dumps excess energy whenever the FLASH 
setting is reduced.  This is the default factory setting. 

Fd.1 

Flash dump on.  This method attempts to reduce the power in the shortest 
possible time whenever the FLASH setting is reduced.  The unit determines 
whether to resistively dump the excess stored energy or to dump it quickly by 
automatically flashing the unit. 

 

INTERMITTENT Option 

The preferred mode for the ‘INTERMITTENT’ function can be selected from the ‘OPTIONS’ sub-
menu as follows: 

Option Description 

In.0 

NORMAL.  Only available when the LAMP is switched ON (

PROP, IND or 100%

).  

The Modelling Lamp will extinguish while the unit recharges and light again when 
the unit reaches ‘READY’.  If the unit fails to flash for any reason then the LAMP 
will not be extinguished.  This is the default factory setting. 

In.1 

PULSE MODE.  Available with the LAMP either ON or OFF.  When the unit 
reaches ‘READY’, after being flashed, the Modelling Lamp will intensify to full 
brightness and then dim before returning to the previous setting (or to OFF).  The 
exact effect will depend on the current lamp setting.  If the unit fails to flash for any 
reason then the LAMP will not follow this sequence. 

 

Summary of Contents for ESPRIT digital DX1000

Page 1: ...FOR THE 1000DX 117V ESPRIT DIGITAL INSTRUCTIONS BWL 0324 1 11 1 02 BOWENS INTERNATIONAL LIMITED 355 OLD ROAD CLACTON ON SEA ESSEX CO15 3RH UNITED KINGDOM Tel 44 0 1255 422807 Fax 44 0 1255 436342 www...

Page 2: ...Number Full power 50 Keylite ISO 100 120m Flash Duration Full Power t 0 5 1 1500s Flash Colour Temperature Approx 5600K UV coated Flash Power Control Full to 1 32 5 f stop in 1 10 increments Recommend...

Page 3: ...Confirm that the fuse is intact and if in doubt replace A spare fuse is fitted in the fuse holder always replace with a fuse of the correct type and rating If the fuse blows immediately the unit is sw...

Page 4: ...reflectors and accessories are available for the Esprit units Slide the neck of the reflector accessory over the front of the unit Align the three pegs with the three slots in the retaining ring pres...

Page 5: ...ired a Wide Angle Reflector should be fitted Then insert the umbrella through the hole in the Wide Angle Reflectors mounting bracket and lock in position with the knurled screw Note Take care when fit...

Page 6: ...the display changes to show one of the values below Release the button If the SOUNDER is on it will sound continuously while the FUNCTION button is held down Now momentarily press the FUNCTION button...

Page 7: ...1 is minimum and 9 is the maximum Use UP or DOWN to adjust Default factory setting is di 7 UP DOWN Buttons Select the required FUNCTION as detailed above Single presses of the UP or DOWN buttons will...

Page 8: ...omatically discharges the capacitors when the power is reduced The READY indicator flashes while the unit is dumping The user may select one of two DUMP methods by means of the OPTIONS sub menu See OP...

Reviews: