SPECIFICATION 

Esprit Digital: 

1000DX 

Stored Energy (Max) 

1000Ws 

Typical Recycle Time 
(Full Power 117V 60Hz) 

2.9 seconds 

Supply Voltage AC 

95-130V 50 or 60Hz 

Stabilisation 

+/- 0.05 f-stop 

Modelling Lamp 

Max 275W 

Ready Indication 

Green ‘READY’ 

LED 

at 100% 

Audible and Modelling light indication as selected. 

Fuse 

10A (T) 20mm  

Nominal Sync. Voltage 

14V 

Photocell On/Off 
Sounder On/Off 
Modelling Power Control 

Off / Proportional / Independent / 100% 

IR Remote Control 

Full control, 12 channels, No. depends on transmitter 

Guide Number:  
Full power, 50

°

 Keylite, ISO 100 

120m 

Flash Duration (Full Power) t=0.5 1/1500s 
Flash Colour Temperature 

Approx. 5600K (UV coated) 

Flash Power Control 

Full to 1/32  5 f-stop in 1/10 increments 

Recommended Modelling Lamp 

250W 120V Halostar 
275W 120V Photoflood 

BW-1024/B 
 

Flash Tube Assembly 

UV-Coated 

BW-1079 

Dimensions L 

=450mm 

W=170mm 
H =125mm 

Weight 4.4Kg 

 

Due to our policy of constant product improvement Bowens International Limited reserve the right 
to change equipment specifications without notice. 

ACCESSORIES 

For details of all related products please contact your local distributor. 

Lamp Function Control

Test / Open Flash

Ready LED 

Function Display Controls 

Function Display

IR Remote 

Receiver 

AC Connection

Fuse (+ Spare Fuse)

Sync 
Socket 

Power  
On/Off Switch

Summary of Contents for ESPRIT digital DX1000

Page 1: ...FOR THE 1000DX 117V ESPRIT DIGITAL INSTRUCTIONS BWL 0324 1 11 1 02 BOWENS INTERNATIONAL LIMITED 355 OLD ROAD CLACTON ON SEA ESSEX CO15 3RH UNITED KINGDOM Tel 44 0 1255 422807 Fax 44 0 1255 436342 www...

Page 2: ...Number Full power 50 Keylite ISO 100 120m Flash Duration Full Power t 0 5 1 1500s Flash Colour Temperature Approx 5600K UV coated Flash Power Control Full to 1 32 5 f stop in 1 10 increments Recommend...

Page 3: ...Confirm that the fuse is intact and if in doubt replace A spare fuse is fitted in the fuse holder always replace with a fuse of the correct type and rating If the fuse blows immediately the unit is sw...

Page 4: ...reflectors and accessories are available for the Esprit units Slide the neck of the reflector accessory over the front of the unit Align the three pegs with the three slots in the retaining ring pres...

Page 5: ...ired a Wide Angle Reflector should be fitted Then insert the umbrella through the hole in the Wide Angle Reflectors mounting bracket and lock in position with the knurled screw Note Take care when fit...

Page 6: ...the display changes to show one of the values below Release the button If the SOUNDER is on it will sound continuously while the FUNCTION button is held down Now momentarily press the FUNCTION button...

Page 7: ...1 is minimum and 9 is the maximum Use UP or DOWN to adjust Default factory setting is di 7 UP DOWN Buttons Select the required FUNCTION as detailed above Single presses of the UP or DOWN buttons will...

Page 8: ...omatically discharges the capacitors when the power is reduced The READY indicator flashes while the unit is dumping The user may select one of two DUMP methods by means of the OPTIONS sub menu See OP...