13. 

Replacing the Flashtube 

Warning High Voltage 

Do not touch the flashtube assembly for thirty minutes after 
disconnecting from supply. 

Switch off the unit, disconnect from the mains supply and then wait thirty 
minutes before touching / removing the flashtube.  

Remove the glass dome as described in section 12.  Unwind the twisted 
Trigger wire from the trigger terminal tag, and gently pull the flashtube 
assembly out of the unit.  

Hold the replacement assembly as shown in Fig.3 and locate the three brass 
sockets onto the plugs in the front of the unit.  Press down evenly until all the 
plugs and sockets are fully engaged.  Pass the trigger wire through the hole in 
the trigger terminal tag and wind around the tag, ensuring that the wire does 
not touch the metal top hat.   

Refit the glass dome as described in section 12.  Discard the old flash tube 
safely using the packaging from the new tube. 
 

 

 

FIG. 3  FLASH TUBE ASSEMBLY

 

 

Summary of Contents for ESPRIT 1500

Page 1: ...ESPRIT 1500 BW 1072 OPERATING INSTRUCTIONS...

Page 2: ...Off Switch 5 Modelling Lamp Control Switch 6 Photocell On Off Switch 7 Sounder On Off Switch FIG 2 SIDE VIEW 1 Latch Knob 2 Flash Power Control 3 Ready Indicator 4 Photocell Cover 5 Test Open Flash 6...

Page 3: ...frosted domes are also available as accessories for special applications 2 Safety Notes The Esprit 1500 must not be used in an environment where moisture or flammable vapour is likely to come in conta...

Page 4: ...n Two Esprit 1500 flash units may be connected together using a y connector An Infra Red Receiver or Omnicell may also be plugged into this socket 7 Flash Power Selection Indication The Flash Power Se...

Page 5: ...neck of the reflector over the front of the unit Align the three pegs on the reflector with the three slots in the retaining ring press down and turn clockwise to lock To remove the reflector press t...

Page 6: ...wire from the trigger terminal tag and gently pull the flashtube assembly out of the unit Hold the replacement assembly as shown in Fig 3 and locate the three brass sockets onto the plugs in the fron...

Page 7: ...re Approx 5600 K UV coated as standard Modelling Power Control Independent fully variable Ready Indication 100 of charge Supply Voltage AC 190 250 VAC 50 Hz Voltage Stabilisation 1 Fuse 10 A F Sync Vo...

Page 8: ...owens Esprit 1500 Operating Instructions 8 Esprit 1500 Instructions BW 1072 BWL 0235 1 BOWENS INTERNATIONAL LIMITED 355 Old Road Clacton on Sea Essex CO15 3RH Tel 44 0 1255 422807 Fax 44 0 1255 436342...

Reviews: