DN3816 

 

There are two possible configurations for inputs IN 1 to IN 4: Line input (0 dBm) or Micro input (-52 dBm). In addition, 
when audio inputs 1 and 2 are set to Micro, these can be supplied a phantom power supply for powering electret 
microphones. Whichever configuration is to be used, follow the procedure below to set the inputs according to the 
desired application. 

To change the audio input type (IN 1, IN 2, IN 3 and IN 4), place the relevant jumper on the corresponding MIC or 
LINE pins as required. To enable a phantom supply (SUPPLY 1 and SUPPLY 2) on the corresponding inputs IN 1 or 
IN 2, fit the corresponding SUPPLY jumper: 

 

First ensure that the DN 3816 is switched off and that the power cable is unplugged before opening up the 
unit. 

 

To avoid electrostatic discharges, first ground yourself using an earthing lead before opening up the DN 
3816. 

 

Open the cover by undoing the two screws on the rear panel. 

 

Locate the jumpers on the interface board located on the unit’s rear plane and place them in the required 
positions. 

Summary of possible configurations: 

 

IN 1 

IN 2 

IN 3 

IN 4 

 

Type 

Jumper 

Type 

Jumper 

Type 

Jumper 

Type 

Jumper 

Select 

Micro/Line 

Mic 
Line 

IN1 MIC 
IN1 LINE 

Mic 
Line 

IN2 MIC 
IN2 LINE 

Mic 
Line 

IN3 MIC 
IN3 LINE 

Mic 
Line  

IN4 MIC 
IN4 LINE 

Phantom power 

SUPPLY 1: YES/NO 

SUPPLY 2: YES/NO 

NO 

NO 

 

 

 

 

 

8.2 

Software configuration 

8.2.1 

Functional definition 

This section covers all the parameters that need to be set to determine how the matrix should work. 

8.2.1.1 

Setting the audio input source parameters 

These parameters can be set under the « 

Sources Types » tab. 

An audio input signal can be directed (switched) to one of the audio output channels if the audio input 
channel has been activated. An audio input channel may be activated by several trigger signals which 
depend directly on the parameter set under the « 

Sources Types » tab. The various trigger types are:  

 

Modulation detection 

 

Data link 

 

Persistent 

 

GPI remote control 

 

GX 3016 

 

External 

In addition, each source type may be set to either « Speech » or Music. The complete range of source 
types available is therefore as follows: 

 

Speech type 

o

 

Speech sound detection 

o

 

GPI remote controlled speech 

o

 

GX 3016 

o

 

Data link 

 

Music type 

o

 

Persistent music 

o

 

Music sound detection 

o

 

GPI remote controlled music 

IMPORTANT: As regards inputs IN 1 and IN 2, ensure that jumpers SUPPLY 1 and SUPPLY 2 are 
not fitted if the input is configured as a Line input, otherwise the unit will not operate correctly. 

N.B.: Audio inputs IN 5 to IN 8 are fixed Line inputs and cannot be changed. 

 

Summary of Contents for DN 3816

Page 1: ...block 8 5 3 5 Serial Number label 8 5 3 6 Analog Inputs 1 to 8 8 5 3 7 Analog Outputs 1 to 16 8 5 3 8 24 V socket 8 5 3 9 MAC address 8 5 3 10 Ground point 8 5 3 11 Mains block 8 5 3 12 ON OFF switch...

Page 2: ...ect of equalisation on voice sounds 18 8 2 2 2 2 Setting Mute on the audio outputs 18 8 2 2 2 3 Adjusting Delay on the audio outputs 18 8 2 2 2 4 Adjusting Volume on the audio outputs 18 9 MONITORING...

Page 3: ...GXT4000 1 x RS232 interface for communication with external equipment 1 x EtherSound interface The following digital audio processes can be applied to each audio input level adjustment bass treble adj...

Page 4: ...ase the server application is notified by the DN 3816 when actions are achieved this is possible for example when a source switching is always operated on one or several zones of the same matrix and w...

Page 5: ...e 5 band equalization delay settings to do on outputs side Example n 1 transportation of 16 audio signals between 2 distant places through optic fiber link 8 signaux audios 1 8 8 audio signals 1 to 8...

Page 6: ...k IN Network OUT DN3816 Network IN Network OUT Ethernet Fibre Optique Ethernet to optic fiber Ethernet Fibre Optique Ethernet to optic fiber Ethernet Fibre Optique Ethernet to optic fiber Ethernet Fib...

Page 7: ...ered on 5 2 3 Green STATUS indicator When lit this indicates that the digital signal processing and control functions of the DN 3816 matrix are working correctly 5 2 4 Green input SIGNAL indicators Th...

Page 8: ...number of the DN 3816 5 3 6 Analog Inputs 1 to 8 The analogue inputs connector strip consists of 8 balanced analogue audio inputs 5 3 7 Analog Outputs 1 to 16 The analogue outputs connector strip cons...

Page 9: ...mes and that air flow around the unit is not restricted Ensure there is sufficient room at the rear of the unit at least 100 mm to connect the cables Warning DSP Transformateur Transformer Pr ampli Li...

Page 10: ...he consoles on the same RS485 bus occupy just one audio channel The consoles determine automatically which gets to use occupy the single audio channel Bus 1 of the DN 3816 uses audio input 5 and bus 2...

Page 11: ...816 matrix has 8 opto coupled logic general purpose inputs or logic GPIs Switches or relay contacts of external equipment may be connected directly to the GPIs to achieve the operation required The GP...

Page 12: ...Use the ON OFF switch on the mains block on the rear panel to switch on the matrix unit The green ON indicator will light to show the unit is powered up Once the unit has initialised which takes less...

Page 13: ...trix Hardware configuration o Setting the audio input s physical parameters Mic Line phantom power Software configuration o Functional definition Types of source Priorities Declaration of groups Confi...

Page 14: ...MIC IN1 LINE Mic Line IN2 MIC IN2 LINE Mic Line IN3 MIC IN3 LINE Mic Line IN4 MIC IN4 LINE Phantom power SUPPLY 1 YES NO SUPPLY 2 YES NO NO NO 8 2 Software configuration 8 2 1 Functional definition T...

Page 15: ...player or satellite receiver 8 2 1 1 4 GPI remote control An input channel may be selected using a dry contact type logic GPI A switch may be connected to one of the GPIs in order to switch an input c...

Page 16: ...GX 3016 address 2 console may be configured with an audio output to switch the audio input 6 that of the GX 3016 2 to the chosen audio output In addition each key on the GX 3016 address 1 console may...

Page 17: ...Mute function This is used to deactivate the input signal 8 2 2 1 4 Adjusting Volume on the audio inputs Once all the audio input settings have been adjusted the general volume of each input needs to...

Page 18: ...output needs to be set The volume may be set from between 60 and 10 dB using the output volume potentiometer To get the maximum dynamic range from the signal processing processor the output volume sh...

Page 19: ...19 DN3816...

Page 20: ...100Hz 1Khz 10Khz 10 6 EtherSound Connectors RJ45 Network In and Network Out 10 7 GPI Specifications Number of inputs 8 Type opto isolated 10 8 GPO Specifications Number of outputs 16 open collector o...

Page 21: ...ction Music IN 4 Modulation Detection Speech IN 5 GX 3016 IN 6 GX 3016 IN 7 Modulation Detection Music IN 8 Persistent music 12 1 3 Default configuration of priority levels AUDIO INPUTS IN 1 IN 2 IN 3...

Page 22: ...up number 1 Select output Out 1 2 Select output Out 2 3 Select output Out 3 4 Select output Out 4 5 Select output Out 5 6 Select output Out 6 7 Select output Out 7 8 Select output Out 8 9 Select outpu...

Page 23: ...ues of the audio signal processing parameters are given in the table below Function Parameter Value Comment Input volume Gain Attenuation 0 db For all inputs Status Inactive Noise Gate Threshold 90 dB...

Reviews: