DOC: BOS0295
User Manual PD301 Play Detector
14
5.0
Troubleshooting
TROUBLE
POSSIBLE CAUSES
SOLUTION
Play Detector does not operate
- No electric supply.
- Cable connections.
- Internal fuse burnt out.
- Main power switch is off
- Emergency stop activated
- Circuit protector activated
- Check three phase supply
- Check all connections.
- Replace
- Switch on
- Deactivate emergency stop
- Deactivate circuit protector
Power is on but no plate movement
- Emergency stop activated
- Deactivate emergency stop
- Wrong control selected
- Select desired control
Torch does not switch on
- LED cluster damaged or faulty
- Check / replace cluster
Torch does not operate plates
- Data cable or keypad damaged
- Wrong control selected
- Check / replace
- Select desired control
Motor operates but no plate
movement
- Oil level too low
- Bad connection on solenoid actuator
- Software error
- Add oil
- Check internal connections
- Contact service agent