3-12
255 Conquest
Section 3 • Systems & Components Overview & Operation
R
REFER TO THE MANUFACTURER’S MANUAL IN
YOUR OWNER’S MANUAL PACKET FOR COMPLETE
INSTRUCTIONS AND WARRANTY.
Head System
Environmental Considerations
The Environmental Protection Agency (EPA)
standards state that in freshwater lakes, reservoirs,
impoundments whose inlets or outlets are such as
to prevent the ingress or egress by vessel traffi c
subject to this regulation, or in rivers not capable
of navigation by interstate traffi c subject to this
regulation, marine sanitation certifi ed by the United
States Coast Guard (U.S.C.G.) installed on vessels
shall be designed and operated to prevent the
overboard discharge of sewage, treated or untreated
or any other waste derived from sewage.
The EPA standards further state that this shall
not be construed to prohibit the carriage of Coast
Guard certified flow through treatment devices
which have been secured so as to prevent such
discharges. They also state that the waters where
a Coast Guard certifi ed marine sanitation device
permitting discharge is allowed include: Coastal
waters, Estuaries, The Great Lakes and Intercoastal
waterways, Freshwater lakes and Impoundments
accessible through locks and other fl owing waters
that are navigable interstate by vessels subject to
this regulation. (40CFR 140.3)
Head System (Standard)
Fig. 3.12.1
WASTE CONTAINMENT UNIT
WATER TANK
WASTE TANK
The 255 Conquest is fi tted with a Sani-Potti waste
contaiment system located in the cabin. The system
includes a Sani-Potti unit, vent and associated hoses
and clamps. The Sani-Potti unit has a lower tank and
an upper tank. The upper tank holds freshwater used
for fl ushing the system. The lower tank has a waste
containment capacity of 5.2 Gal. (19.7 L).
A dockside discharge deck plate is located on the
starboard gunwale and is marked “WASTE”. Access
is gained by use of a special key that is included in
the owners manual packet.
The dockside facility will have a connection to fi t
your boat.
1
2
3
2
3
4
5
6
NOTICE
This boat may be equipped with a direct
overboard discharge valve. Discharging of
sewage directly overboard is for use where
approved only.
Damage to the system could occur if
the discharge seacock is not open during
operation.
FWD
DISCHARGE HOSE
VENT HOSE
DISCHARGE DECK PLATE
1
4
5
6
Summary of Contents for 255 Conquest
Page 2: ......
Page 18: ...xviii 255 Conquest R THISPAGE INTENTIONALLY LEFT BLANK ...
Page 90: ...4 6 255 Conquest Section 4 Electrical System R Switch Panel Diagram Fig 4 6 1 ...
Page 91: ...4 7 Section 4 Electrical System 255 Conquest R DC Wiring Diagram Fig 4 7 1 ...
Page 94: ...4 10 255 Conquest Section 4 Electrical System R THIS PAGE INTENTIONALLY LEFT BLANK ...
Page 106: ...5 12 Section 5 Care Maintenance R 255 Conquest THIS PAGE LEFT INTENTIONALLY BLANK ...