-11-
REPLACEMENT PARTS:
Use only Genuine OEM replacement parts.
ASSEMBLY PROCEDURE FOR SEALS:
When repairing a tool, make sure the internal parts are clean and lubricated. Use Parker “O”-LUBE or equivalent
on all “O”-rings. Coat each “O”-ring with “O”-LUBE before assembling. Use a small amount of oil on all moving
surfaces and pivots. After reassembly add a few drops of BOSTITCH Air Tool Lubricant through the air line
fitting before testing.
AIR SUPPLY-PRESSURE AND VOLUME:
Air volume is as important as air pressure. The air volume supplied to the tool may be inadequate because of
undersize fittings and hoses, or from the effects of dirt and water in the system. Restricted air flow will prevent
the tool from receiving an adequate volume of air, even though the pressure reading is high. The results will be
slow operation, misfeeds or reduced driving power. Before evaluating tool problems for these symptoms, trace
the air supply from the tool to the supply source for restrictive connectors, swivel fittings, low points containing
water and anything else that would prevent full volume flow of air to the tool.
TROUBLE SHOOTING
To reduce the risk of serious personal injury, remove fasteners from magazine before
making any adjustments or servicing this tool.
SYMPTOM
CAUSE
FIX
Trigger valve housing leaks
O-ring or valve stem failure
Replace valve using Trigger Valve Kit
Top cap leaks air
Loose cap screws
Tighten cap screws using appropriate hex wrench
Damaged or worn gasket or o-ring
Replace gasket/o-rings using Nailer O-Ring Repair Kit
Exhaust leaks
Main seal or o-ring damaged,
debris in tool.
Replace gasket/o-rings using Framing Nailer O-Ring Repair Kit
Air leaks around nose when tool is
at rest. (Driver blade in up position.)
Damaged or worn o-rings
Replace gasket/o-rings using Framing Nailer O-Ring Repair Kit
Air leaks around nose when tool is
in actuated position. (Driver blade in
down position.)
Damaged or worn bumper
Replace bumper using: Frame Nailer Bumper Kit
Tool does not cycle in cold weather
Tool not receiving air
Check air supply
Valve may be frozen
Warm up tool. Lubricate with BOSTITCH Pneumatic Tool Oil or winter
weight pneumatic oil containing ethylene glycol
Damaged or worn o-rings
Replace gasket/o-rings using Framing Nailer O-Ring Repair Kit
Broken or damaged driver blade
Replace driver blade
Lack of power; sluggish
Low air pressure
Check air supply
Lack of lubrication
Lubricate tool using BOSTITCH pneumatic tool oil
Damaged or worn o-rings
Replace gasket/o-rings using framing nailer o-ring repair kit
Exhaust port blocked or clogged
Disconnect air, remove exhaust plate from top of tool, clean port
Depth adjustment set too shallowly Reset depth adjustment
Driver damaged or worn
Replace driver blade
Skipping nails; intermittent feed
Air restricted
Check air supply and couplers
Lack of lubrication
Lubricate tool using BOSTITCH pneumatic tool oil
Nosepiece screws loose
Tighten nosepiece screws using appropriate hex wrench
Wrong size/angle fasteners
Use only recommended fasteners
Dirty magazine
Clean magazine track and nosepiece
Damaged/Worn magazine
Replace magazine
Broken or damaged driver blade
Replace driver blade
Trigger valve o-ring worn or
damaged
Replace valve using Trigger Valve Kit
Worn piston or feed system o-ring
Replace O-ring using Framing Nailer O-Ring Repair Kit
Fasteners jam in tool
Driver channel in nosepiece worn
Replace nosepiece
Wrong size/ angle fasteners
Use only recommended fasteners
Worn driver blade
Replace driver blade
Nosepiece screws loose
Tighten nosepiece screws using appropriate hex wrench
Nails not feeding properly
Ensure nails are feeding properly through the magazine and into the nose
Nails not feeding properly
Ensure canister platform is set to correct location for nail size being used
Summary of Contents for BTF83C
Page 34: ... 34 ...
Page 35: ... 35 ...
Page 36: ... 36 DEC 2016 Copyright 2016 Part No 9R217400RA BOSTITCH BTF83C ...