Boste BK Series
7
2no
Adaptors
5no Stem
Elbow
Insulated Faucet Pipe
11.
Connect faucet pipework as follows:
Cold & Ambient Model: Cold, Sparkling & Ambient Model:
-
Fit Stem Elbows directly to water outlets on back of unit.
-
Fit 30mm pieces of pipe to each.
-
Fit Y or Cross Fitting.
-
Fit 30mm piece of pipe
-
Fit male threaded adaptor fitting
-
Fit female threaded adaptor fitting
-
Connect to insulated faucet pipe
12.
(Sparkling Model only). Unpack CO2 Regulator and fit elbow fitting to spigot outlet. Check the control knob is oin
the fully closed position (anticlockwise). Carefully screw fit to a new, full CO2 single use cylinder ensuring the
small pressure relief vent in the stem is facing away from you or anyone else. Hand tighten securely. Connect to
the CO2 inlet on the back panel using the required length of ¼1/4” pipe. Stand cylinder in a suitable place.
13.
Fit optional Drip Tray at this stage (if selected)
14.
Turn on the water supply and check for any leaks.
15.
Connect the IEC power cordset to the electricity supply. The Direct Chill system should now be heard to begin
filling. This may continue for a few minutes depending upon water pressure. (NB: Any immediate whining noise
from the DC pump should soon stop as the water level in the system rises).
16.
Upon the filling cycle completing, proceed to flush the cold and the ambient water channels using these buttons on
the faucet control panel. We recommend that a minimum of 10lts is flushed through the unit*. (Cold approx. 8 lts
and Ambient approx. 2 lts). Switch on the Cooling Mode and allow up to 1 hr for the initial cooling cycle.
17.
(Sparkling Model only). Switch on Sparkling Mode and allow the carbonation tank to fill. (The carboanntion pump
will run for approx. 15-20 secs). Upon completion, open the CO2 Regulator Knob and set initially to 5 bar. Flush
through approx. 10 lts of water using the sparkling button*. Depending on the inlet water pressure, you may have
to pause approx. every 500ml to allow the carbonation tank to refill. Reset the CO2 pressure to the required level.
We recommend 3-5bar (max) depending on individual requirements. Allow up to 1 hr for carbonation to develop.
*NB: The integrated leak prevention control will prevent any continuous dispense of >60 secs and could occur
while carrying out this prolonged dispensing. When it occurs the dispense will stop and a bleeping noise will
sound. To reset momentarily release the button and press again
2no Stem
Elbow
Y Fitting
Cross
Fitting
2no
Adaptors
CO2 Regulator &
Cylinder
Summary of Contents for UDC102
Page 1: ...1 PRODUCT MANUAL Boste BK Series UDC102 Undersink Dispenser Model ...
Page 16: ...Boste BK Series 16 Diagrams Parts Lists ...
Page 17: ...17 ...
Page 18: ......
Page 19: ......
Page 20: ......
Page 21: ......
Page 22: ...Boste BK UDC102 ...
Page 23: ......
Page 24: ......
Page 25: ......
Page 26: ......
Page 27: ......