15
Parameter List
ASSIGN
ASSIGN COMMON
Parameter
Explanation
SENS (INPUT SENS)
This adjusts the input sensitivity when INPUT LEVEL is selected for SOURCE.
ASSIGN 1–8
Parameter
Value
Explanation
SW
OFF, ON
Turns the ASSIGN 1–8 on/off.
SOURCE
Specifies the controller (source).
TAP/CTL
[TAP/CTL] switch.
EXP PDL
(EXP PEDAL)
External footswitch (EV-5 etc.; available separately) connected to the CTL 1,2/
EXP jack.
CTL1, 2 PDL
External footswitch connected to the CTL 1,2/EXP jack.
INT PDL
Internal pedal
The virtual expression pedal will begin operating when started
by the specified trigger (TRIGGER), modifying the parameter
specified by “TARGET.”
For details on the parameters that can be assigned to the
internal pedal, refer to “TIME” and “CURVE” (p. 16)
WAVE PDL
Wave pedal
The virtual expression pedal will cyclically modify the parameter specified by
“TARGET” in a fixed wave form.
INPUT
(INPUT LEVEL)
The assigned target parameter will change according to the input level.
* If you want to adjust the input sensitivity, set the SENS (INPUT SENS).
CC#1–31, CC#64–95
Controller number from an external MIDI device
MODE
(SOURCE MODE)
Specifies the operation of the controller.
MOMENT
The value will normally be OFF (minimum value), and will be ON
(maximum value) only while the control is being operated.
* If you want to use the internal pedal or wave pedal, set to “MOMENT.”
TOGGLE
The value will toggle between OFF (minimum) and ON (maximum) each time
the control is operated.
TRG
This selects the parameter to be changed.
MIN (TARGET MIN)
MAX (TARGET MAX)
Specifies the range of change for the parameter. The values will depend on the parameter that’s
assigned by “TARGET.”
ACT.LO
(ACT RANGE LO)
Within the operating range of the source, this specifies the range that will control the target
parameter.
The target parameter will be controlled within the range specified. Normally, you should leave ACT.LO
at “0” and ACT.HI at “127.”
ACT.HI
(ACT RANGE HI)
WAV.RT
(WAVE RATE)
*1
0–100,
BPM –
Specifies the time for one cycle of the wave pedal.
* If, due to the tempo, the time is longer than the range of allowable settings, it is then synchronized
to a period either 1/2 or 1/4 of that time.