Celsius Platinum Inverter Heat Pump
Installation & User Manual
18
*Above data is subject to modification without notice.
DIMENSIONS
Unit = mm
A
B
C
D
E
F
G
H
PL13HP
407
528
390
432
893
280
74
650
PL17HP
407
574
390
432
939
350
74
650
PL21HP
407
630
390
432
995
460
74
750
PL26HP
407
760
384
429
1125
600
74
952
PL32HP
407
710
493
539
1074
640
74
947
Heat Pump Installation
Wiring & protecting devices and cable specification
5.2.2
5.2.3
When the heat pump is running, condensation will occur and drain from the bottom of the
unit. This is completely normal. However, consideration should be made for how to drain the
condensation away. Drainage nozzle and pipe are supplied.
Connect to appropriate power supply. The voltage should comply with the rated voltage of the unit.
Earth the machine well.
Wiring must be handled by a professional technician according to the circuit diagram.
Set leakage protector according to the local code for wiring (leakage operating current ≤ 30mA).
The layout of power cable and signal cable should be orderly and not affect each other.
1
2
3
4
5
!
ATTENTION
Switch on after finishing all wiring construction and re-checking.