24
309416
01/31/2012
Operation
7.2 Emergency Shutdown Procedure
In the event of an emergency and the 210 DUS Air Compressor must be stopped suddenly without first
unloading the compressor, the machine is equipped with an emergency shutdown switch. Do not shut
the machine off loaded except in an emergency situation. Do not operate this machine again until the
problem has been properly resolved.
I.
Emergency Shutdown Procedure
A. Flip up the red emergency stop switch cover on the instrument panel.
B. Flip the toggle switch up to immediately shutdown the machine.
C. Once the machine has stopped, flip the shutdown switch and cover back down.
D. Fix the problem that required the emergency shutdown.
E. Remove the side panel and replace the 20 amp fuse on the rear of the instrument panel.
Shutting down the machine under load will damage the engine,
drive coupling, and/or the airend. Follow normal shutdown
procedure at all times.