background image

 
 
 
 

Caution 

 

This Reverse Osmosis system is designed for operation on microbiologically safe water 
which is usually Chlorinated mains water supplies, this system is not suitable for 
installation on Un-Chlorinated water supplies, contact your selling agent to have a UV 
steriliser added for microbiologically unsafe water such as Tank, Dam or Bore water. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

Sediment Filter 
Stage 1

Reverse Osmosis 
Membrane Stage 3 

Carbon Post Filter 
stage 5 

Pressurised Storage 
Tank 

Membrane Flushing 
Valve/ Flow Restrictor 

Re-mineraliser cartridge 
Stage 4 

Carbon Filter  
Filter Stage 2 

 

Stage 1

  Sediment pre-filter, this filter is a 1 micron polyspun sediment filter cartridge 

for mechanical removal of Grit, dust, Rust, mud, algae ect. This cartridge is 
normally replaced every 12 months but if dirty mains water is encounted more 
frequent change may be required. 

 
Stage 2 

   Carbon pre-filter, this filter is a high grade chloramine carbon cartridge to 

protect the membrane from chlorine and ammonia which can damage a TFC 
(thin film composite) membrane, this carbon cartridge will also assist the 
membrane by removing THMs, TCEs, pesticides and other organic pollutants. 
This cartridge is usually changed every 12 months unless very dirty from the 
mains supply is encountered or very heavy usage. 

 

Summary of Contents for 021-5RM boss water systems australia

Page 1: ...rsion that is available on our web site it is a shorter version due to other suppliers likely to copy this instruction manual as their own This reverse osmosis system is designed to have the strongest re mineralising possible and longer lasting compared to the in line version it s target is 7 0 pH so those looking for high alkaline water this unit won t do it in standard form but the re mineralisi...

Page 2: ... waste as such the reverse osmosis process is a selection process if the water molecule is pure it will pass into the pure water part anything else is rejected The reverse osmosis process is the best water purity of any type of process and is similar to Distillation but distilled water is almost devoid of oxygen and tastes flat and dead reverse osmosis water process actually adds oxygen to the wat...

Page 3: ... 4 Carbon Filter Filter Stage 2 Stage 1 Sediment pre filter this filter is a 1 micron polyspun sediment filter cartridge for mechanical removal of Grit dust Rust mud algae ect This cartridge is normally replaced every 12 months but if dirty mains water is encounted more frequent change may be required Stage 2 Carbon pre filter this filter is a high grade chloramine carbon cartridge to protect the ...

Page 4: ...se a location for the storage tank the tank can be more remote than the main filter system a back corner cupboard is often used the tank tube line is 1 8 metres try to have as short a tube to the tank and faucet as practicable because the shorter the tube the faster the flow will be All tube is colour coded for installation ease Blue tube connects from the mains supply to the entry point of the un...

Page 5: ...e end of the tube as far as it will go Insert the tube into the base of the threaded part of the faucet push it in firmly about and slide nut up to thread and tighten firmly do not over tighten Storage Tank Place storage tank in a convenient position Tank can be placed on its stand either upright or on its side Activating the System For the First Time First open the Faucet turn Feed Water Valve co...

Page 6: ...for about 10 minutes to clear any possible build up of particles failure to do this will shorten membrane life This flush valve needs to be operated when the tank is filling if you open the valve and nothing happens the system is in shut down mode release some water from the faucet to start the unit filling again and open the flushing valve again Drain the tank as part of the membrane flushing pro...

Reviews: