38
Revision Date: 02/07/2020
Revision: C
Pre-Assembled Rhino - Installation Manual
When running my hand over the panels, some areas are hot to touch
Cause:
While conducting the final commissioning of the system you noted that a section of the collector panels
appears noticeably hotter to touch compared to other sections of the panel. While it is normal for the top of
the panels to be slightly warmer than the bottom, no part of the panel(s) should be hot. Hot spots indicate
that there is no/low water flow through this part of the panel. This can be due to two factors, issues with the
pump or improper installation, you can find out what the cause is by:
•
Checking your calculations
go back and check that you have calculated and selected the right sized pump for your installation. If
you have not, then this is likely to be the problem.
•
If your calculations are correct,
then your issue is most likely going to be due to improper installation
Solution:
When the issue has been identified as:
The pump
Improper installation
•
Be sure that the filter is clean and
backwash to reduce pressure
•
The pump may not be big enough to
provide the system with enough water. You
can check this by using a flow meter.
Increase the pump horsepower as required
•
If the pool is using a suction type pool
cleaner, try removing it to see if this
eliminates the issue. If it does, only use the
cleaner while the system is turned “OFF”
•
If the system is a single row array with
adequate flow, try increasing the back
pressure by fitting a ball valve to the return
pipe and slightly adjust the valve to provide
additional internal water pressure and even
out the flow throughout the panels
•
Check that you have not exceeded the
maximum allowance of panels for a
continuous row. If you have, then change
the array to an appropriate double row or
single row split feed configuration
•
If the installed system is a double row or
single row split feed system with an
adequate flow, try installing a ball valve on
the return side of the set of panels that are
the coolest to the throttle. Adjust the ball
valve to back the flow through the system
and force more water through the warmer
panels.