background image

PE08TW8

OPERATING INSTRUCTIONS

Three Stage Torque Wrench Pump

WARNING

Read and follow all Safety Instructions, Warnings, Cautions and  

Important information provided in this manual before using the 

equipment. They are provided for the safety of those operating the 

equipment and to prevent personal injury and/or damage to property 

when using this equipment. 

THIS EQUIPMENT SHOULD ONLY BE USED BY OPERATORS 

WHO HAVE BEEN TRAINED IN THE SAFE USE OF HIGH 

PRESSURE HYDRAULIC EQUIPMENT

www.bosshydraulics.com.au

Form: BM008

Summary of Contents for PE08TW8

Page 1: ...vided in this manual before using the equipment They are provided for the safety of those operating the equipment and to prevent personal injury and or damage to property when using this equipment THI...

Page 2: ...lease consult Boss Hydraulics for authorised consent Without the written consent from Boss Hydraulics any modifications are not covered by warranty Do not overfill the hydraulic tank If the tank is ov...

Page 3: ...6 Never use pump near flames 1 7 Do not adjust the internal pressure relief valve CAUTION Only use the recommended ISO46 grade oil Do not use the pressure regulator as a general adjustment valve or r...

Page 4: ...ump by the hose 1 MAINTENANCE CHECK 1 Check before operation 1 1 Check if all connections are clean and secure 1 2 Check whether the amount of oil in reservoir are correct and check for any oil spills...

Page 5: ...of the oil changes 4 3 When water enters the reservoir WARNING If oil splashes into your eyes rinse immediately with water for at least 15 minutes If the oil splashes on your skin wash it with water a...

Page 6: ...1 Oil tank 8 Oil unloading hole 2 Pressure setting valve 9 Electronic control system 3 Pressure gauge 10 Tank cover 4 Protection frame 11 Direction valve 5 Motor 12 Quick coupler 6 Cooler 13 valves 7...

Page 7: ...engaged 3 Remote control handle operation instructions 3 1 There is one jog button to advance and retract cycle the wrench and one ON OFF switch on the remote control pendant 5 2 Press the ON OFF swit...

Page 8: ...circuit board allows for simple operation and maximum safety Some of these features are as follows 4 1 The hydraulic electric pump will turn off after no operation has been received after approximate...

Page 9: ...BM008 V1 9 4 HYDRAULIC SCHEMATIC DIAGRAM...

Page 10: ...he power supply power connection etc turn on the power No pressure Quick couplers not well connected Disassemble and reconnect No oil in the tank Add oil to the tank There is not enough oil inside the...

Page 11: ...Oil mixed with oil Change the hydraulic oil Oil inside the tank is not enough Add oil Air in system Air run the system repeatedly several times exhaust air Throttle manual check valve is not in place...

Page 12: ...BOSS HYDRAULICS Head Office 19 Ricketts Road Mt Waverley VIC 3149 I P 1300 BOSS HYD 1300 267 749 E sales bosshydraulics com au I W www bosshydraulics com au...

Reviews: