66
Troubleshooting
Problem
What to check
T1 is plugged
in, power switch
is on, but no
power.
Make sure you have power at the AC outlet. Try operating a lamp or other
equipment from the same AC outlet or test the outlet using an AC outlet tester.
If using the T1 with an L1
TM
model II system:
• Make sure the ToneMatch cable is properly connected to the audio engine
and the L1 power stand.
• Make sure the L1 power stand is turned on and the power LED is blue.
If using the T1 with an L1 model 1 system:
• Make sure the audio engine is properly connected to the T1 audio engine
power supply.
• If available, try a different audio engine power supply.
T1 is on, but
there is no
sound.
• Make sure the Master volume control is turned up.
• Verify that the input channel(s) you want to hear are not muted.
• Check that the volume control is turned up for the channel you want to hear.
• Make sure the appropriate input channel trim control has been tuned up
enough so that the green LED is on (indicating that there is a strong input
signal).
• Check the Prefs (Preference) Input and Output level meters to confirm that
there is a signal at both the input and output stages.
• Make sure volume control is turned up on your input source (instrument).
• Connect your input source (instrument) to the audio engine using a
different cable.
• Plug your input source (instrument) directly into the L1
TM
power stand or a
different amplifier to make sure the source is working.
• Turn the audio engine off and wait 30 seconds. Then turn the unit on
again.
If using the T1 with an L1 model II system:
• Turn off the power stand, re-seat the ToneMatch
TM
cable plug in the
ToneMatch port and turn on the power stand again.
• If available, try a different ToneMatch cable. If another ToneMatch cable is
not available, try a standard Ethernet cable.
• Connect the T1 Master output to the Analog Input on the power stand using a
¼” phone plug cable. Turn up the power stand trim control and verify that you
hear sound.
• Make sure the power LED on the power stand is blue. If it is red, the problem
is in the power stand.
If using the T1 with an L1 model I system:
• Make sure the T1 Master output is connected to the Channel 3 or 4 Line IN
on the power stand. Turn up the power stand Channel 3 / 4 line input level
and verify that the system is producing sound.
• If using the R1 remote control with the system, make sure the R1 Master
volume is turned up.
• Make sure the power LED on the power stand is green. If the LED is red or
yellow, the problem is in the power stand.
Summary of Contents for T1 ToneMatch
Page 10: ...10 Figure 2 T1 ToneMatch Audio Engine Exploded View ...
Page 52: ...52 Figure 3 DSP PCB Top Component Layout and Etch Circuit Board Layout Diagrams ...
Page 53: ...53 Figure 4 DSP PCB Top Component Layout and Power Layer Etch Circuit Board Layout Diagrams ...
Page 54: ...54 Figure 5 DSP PCB Top Component Layout and Ground Layer Etch Circuit Board Layout Diagrams ...
Page 55: ...55 Figure 6 DSP PCB Bottom Component Layout and Etch Circuit Board Layout Diagrams ...