PRO.BOSE.COM

Maintenance

Maintenance

Firmware & Software Updates

Bose periodically releases updates for the CSP firmware. Follow the steps below to update the firmware of 

your CSP.
1.  Open the CSP configuration utility (see 

Accessing the CSP Configuration Utility

 on page 17).

2.  Access 

Settings

 > 

Firmware

 > 

Select File

.

3.  Select the firmware file on your computer, and then click 

Open

.

4.  In the browser window, click 

Update

.

CAUTION:

 Do not disconnect the CSP from your computer until you see a message that the update is 

complete. Interrupting the connection can damage the firmware on the CSP.

Battery Replacement

The CSP-428 and CSP-1248 each contain a replaceable lithium battery for maintaining the real-time clock 

(RTC) capability of the system. This battery lasts at least 10 years from the time of production and rarely 

requires replacement.

Summary of Contents for CSP-1248

Page 1: ...CSP 428 CSP 1248 Commercial Sound Processors Installation Guide Guía de instalación Guide d installation Installationsanleitung Guida all installazione Installatiehandleiding ...

Page 2: ...orage in direct sunlight fire or the like Only use the mounting hardware recommended by the rack manufacturer Due to ventilation requirements Bose does not recommend placing the product in a confined space such as in a wall cavity or in an enclosed cabinet Do not place or install the bracket or product near any heat sources such as fireplaces radiators heat registers or other apparatus including a...

Page 3: ...eraciones no autorizadas a este producto NO use un convertidor de corriente con este producto NO lo use en vehículos o embarcaciones Proporcione una conexión a tierra o asegúrese de que la toma de corriente incorpore una conexión a tierra protegida antes de conectar el enchufe a la toma de corriente de la red eléctrica Si se utiliza la clavija de conexión de red eléctrica o el acoplador del artefa...

Page 4: ...ications non autorisées sur ce produit Veillez à NE PAS utiliser un convertisseur continu alternatif avec ce produit Veillez à NE PAS utiliser cet appareil dans des véhicules ou des bateaux Avant de brancher l appareil à une prise de courant électrique vérifiez que celle ci soit bien raccordée à la terre ou qu elle est dotée d une protection par mise à la terre Lorsque l alimentation de secteur ou...

Page 5: ...rände und Stromschläge zu vermeiden darf dieses Produkt NICHT Regen Flüssigkeiten oder Feuchtigkeit ausgesetzt werden Halten Sie das Produkt von Feuer und Wärmequellen fern Stellen Sie KEINE brennenden Kerzen oder ähnliches auf das Gerät oder in die Nähe des Geräts Nehmen Sie KEINE nicht genehmigten Änderungen an diesem Produkt vor Benutzen Sie das Produkt NICHT mit einem Wechselrichter Verwenden ...

Page 6: ...o dal fuoco e da fonti di calore NON collocare sorgenti di fiamme libere ad esempio candele accese sul prodotto o in prossimità di esso NON apportare alterazioni non autorizzate al prodotto NON utilizzare inverter di potenza con questo prodotto NON utilizzare all interno di veicoli o imbarcazioni Dotare la presa di messa a terra oppure accertarsi che la stessa sia dotata di messa a terra di protez...

Page 7: ...verlagen mag dit product NIET worden blootgesteld aan regen vloeistof of vocht Houd het product uit de buurt van vuur en warmtebronnen Plaats GEEN open vlammen zoals brandende kaarsen op of bij het product Er mogen GEEN wijzigingen aan dit product worden aangebracht door onbevoegden Gebruik GEEN omvormer in combinatie met dit product Gebruik het NIET in voertuigen of boten Zorg voor aarding of con...

Page 8: ...ing 14 Analog Audio Connections 14 AVM 1 14 AmpLink Connection 15 CC 1D CC 2D CC 3D 15 Mute with Standard Contact Closure 15 Control I O Connections 16 Control Inputs 16 Control Output 16 Network Connection 17 Power Connection 17 Accessing the CSP Configuration Utility 17 Maintenance 18 Firmware Software Updates 18 Battery Replacement 18 Troubleshooting 19 Technical Information 20 Technical Specif...

Page 9: ...CSP 428 2 2 mono summed RCA inputs CSP 1248 4 pair CSP 428 2 pair 8 control inputs 1 control output a mute contact Ethernet network for configuration or wall control and Bose AmpLink CSP configuration utility provides an intuitive setup interface via the CSP s integrated web server so that you can quickly configure the CSP using a web browser Rear panel Ethernet connection provides a local port fo...

Page 10: ...ollowing accessories depending on the model CSP 428 or CSP 1248 Accessories CSP 428 CSP 1248 AC power cord 1 1 Cable ties 11 11 2 pin Euroblock orange 1 1 2 pin Euroblock black 1 1 3 pin Euroblock green 1 1 4 pin Euroblock green 1 1 6 pin Euroblock orange 1 2 6 pin Euroblock green 0 3 9 pin Euroblock green 1 1 ...

Page 11: ...1 US black PC 079042 EU white PC 079070 EU black PC 079062 JP white PC 079060 JP black ControlSpace ControlCenter CC 2D PC 079063 US white Uses Network port Requires additional Power over Ethernet PoE switch PC 079043 US black PC 079071 EU white PC 079049 EU black PC 079066 JP white PC 079046 JP black ControlSpace ControlCenter CC 3D PC 079061 US white Uses Network port Requires additional Power o...

Page 12: ...oting on page 19 Signal Signal status indication of all audio input and output channels in order of signaling priority Green Signal present 60 dBFS to 20 dBFS Yellow Signal level optimal 20 dBFS to 2 dBFS Red Clipping 2 dBFS to 0 dBFS Ethernet Connection status indication of Ethernet ports Green Ethernet link established Yellow Active transmission reception AmpLink Connection status indication of ...

Page 13: ... 5 cables or equivalent to make this connection See Installation AmpLink Connection page 15 for more information CAUTION Shielded EIA TIA 568B straight Cat 5 cables or equivalent are required for proper AmpLink operation Unshielded cables are not supported and may cause AmpLink audio to operate improperly Do not connect an AmpLink port to an Ethernet based network t Control Inputs Eight inputs for...

Page 14: ... are balanced Euroblock connectors The termination end of each Euroblock connector includes printed terminal block descriptions The following diagrams show the recommended balanced unbalanced wiring between the audio connectors on the processor and common audio connectors to external audio components To integrate the processor into a telephone switching system use the PBX private branch exchange t...

Page 15: ...d CC 3D can be used for volume and mute control The CC 2D and CC 3D can also be used for source control You can connect these controllers to the Network port via a PoE network switch not included You can connect up to 16 controllers or up to 32 controllers depending on the amplifier you are using with the CSP Use a foiled or unshielded twisted pair F UTP Cat 5e cable not included to connect this p...

Page 16: ...nput to ground Control Output Note The control output is intended for use with ControlSpace Remote only Current Source Devices The control output can power some devices such as LEDs and low current relays directly The maximum source current is 10 milliamps Source Limits Open circuit 8 VDC 2 5 VDC and 10 mA maximum for external devices Current Sink Devices Devices that require more current than is ...

Page 17: ...ng as 40 seconds The processor is fully operable when the Power LED on the front panel is lit solid green Accessing the CSP Configuration Utility To set the functions of the CSP follow the steps below to access the CSP configuration utility hosted on its integrated web server Note The integrated web server is compatible only with Google Chrome Mozilla Firefox Microsoft Edge and Internet Explorer 1...

Page 18: ...ware Select File 3 Select the firmware file on your computer and then click Open 4 In the browser window click Update CAUTION Do not disconnect the CSP from your computer until you see a message that the update is complete Interrupting the connection can damage the firmware on the CSP Battery Replacement The CSP 428 and CSP 1248 each contain a replaceable lithium battery for maintaining the real t...

Page 19: ...et and then reconnect it If the issue continues call your Bose Professional sales support representative The Ethernet LED is off Make sure that the processor s Network port is securely connected to a computer hub or switch using a foiled or unshielded twisted pair F UTP Cat 5e cable not included Make sure that the computer s Ethernet connection is enabled If it is disabled the Link LED on the comp...

Page 20: ...ut phantom power active Maximum Input Level 24 dBu THD N 0 3 20 Hz to 20 kHz 0 dB gain Equivalent Input Noise 117 dBu 22 Hz to 20 kHz 150 Ω input 64 dB gain Phantom Power 48V open circuit 10 mA max per channel selectable per input 80 mA max across all channels Pre Gain Settings 0 14 24 32 44 54 64 dB Audio Outputs Outputs 2 analog balanced Line Level 8 digital AmpLink output Connectors Output Anal...

Page 21: ...Consumption 30 W typical over all mains voltages PSU Max 45 W Mains Connector IEC 60320 C14 inlet Power Dissipation 22 W 75 BTU Hr 19 kcal hr Physical Dimensions H W D 44 mm 483 mm 215 mm 1 7 in 19 0 in 8 5 in Operating Temperature 0 C to 40 C 32 F to 104 F Cooling System Active side venting with fan Storage Temperature 40 C to 70 C 40 F to 158 F Humidity 80 without condensation General Configurat...

Page 22: ...17 dBu 22 Hz to 20 kHz 150 Ω input 64 dB gain Phantom Power 48V open circuit 10 mA max per channel selectable per input 80 mA max across all channels Pre Gain Settings 0 14 24 32 44 54 64 dB Audio Outputs Outputs 2 analog balanced Line Level 8 digital AmpLink output Connectors Output Analog Output orange 3 81 mm pitch 6 pin Digital Output RJ 45 without LED AmpLink output Output Impedance 66 Ω Maxi...

Page 23: ...0320 C14 inlet Power Dissipation 22 W 75 BTU Hr 19 kcal hr Physical Dimensions H W D 44 mm 483 mm 215 mm 1 7 in 19 0 in 8 5 in Operating Temperature 0 C to 40 C 32 F to 104 F Cooling System Active side venting with fan Storage Temperature 40 C to 70 C 40 F to 158 F Humidity 80 without condensation General Configuration Software Integrated web server with configuration utility Network Control Ether...

Page 24: ... 2018 Bose Corporation All rights reserved Framingham MA 01701 9168 USA PRO BOSE COM AM814842 Rev 00 December 2018 ...