background image

7

6 720 606 560

OPERATING INSTRUCTIONS

WARNING!

If the water heater has been damaged or exposed to fire or
sooting, or if any part has been underwater, do not use.
Immediately call a qualified service technician to inspect the
appliance and to replace any part of the control system and
any gas control which as been underwater and to clean the
heater exchanger assembly and water valve.

FILLING

Before proceeding with operation of the water heater make
sure that the system is filled with water:
-

Make sure drain is closed. See figure 8, below.

-

Open a nearby hot water faucet to permit the water to
fill the heater and piping.

-

Close the hot water faucet after the water flows freely
and all air has escaped from the system.

The water heater is now ready to be lit.

Figure 8

SERVICE HINT

The screen (strainer) in the water valve, located in the inlet
of the water valve, may require occasional cleaning due to
foreign material in the water supply. This will restrict the flow
of water and may affect heater operation and prolong filling
time. To inspect the strainer, close the cold water supply
valve ahead of the heater, disconnect the S-bend from the
inlet of the water valve and remove strainer from inlet.
Clean if required, replace strainer in inlet to the water valve,
reconnected S- bend and turn on water supply.

Light the water heater in accordance with the instructions
on the Lighting and Operating Plate on the water heater.
For your convenience, the instructions are repeated here:

LIGHTING AND OPERATING INSTRUCTIONS

1.

STOP! Read the safety information above on this label.

2.

The gas valve must be shut off  by putting the ON/OFF
switch to position “

”. Wait five (5) minutes to clear

out any gas. If you smell gas, STOP! Follow “B” in the
safety information above. If you do not smell gas, go to
the next step.

3.

This water heater is equipped with a safety pilot burner
and an automatic ignition control system.

4.

Set the ON/OFF switch to the “

” position. In this

position, the water heater is ready to use. (See Figure
9).

5.

Turn the hot water faucet on the minimum flow rate
required to activate the heater. The automatic ignition
system first ignites the safety pilot burner which then
ignites the main burner in about 4 seconds. Green LED
indicator is on when main burner is on.

6.

If the red LED indicator light is flashing, this is a warning
that water pressure isn’t enough to ignite the main burner.

7.

The pilot flame will extiguish 10-30 seconds after the
burners come on. The burners will remain on until the
hot water tap is turned off.

NOTE: 

On a first time the initial installation, existence of air

in the gas supply line and in the water line may cause some
ignition delay. In that case, repeatedly open and close the
hot water tap in order to restart the ignition process until all
the air has been purged.

TO TURN OFF GAS TO APPLIANCE

Turn off the manual lever on the gas supply line to the heater
and set the ON/OFF switch to the OFF (

) position.

TO HEAT EX-
CHANGER

WATER VALVE

DRAIN PLUG

FROM HEAT
EXCHANGER

To start and to shut down
the appliance press the
button “

”.

The swit ch is locat ed
behind t he flip down
cover plate on the front
panel strip.

 - on

 - off

Green light on =
main burner on.

Green light off =
main burner off.

If the red light is flashing,
that means the water flow
is not enough to ignite the
burner.

Figure 9

Summary of Contents for WR 400-7.K Series

Page 1: ...not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier READ INSTRUCTIONS CAREFULLY BEFORE INSTALLING ELECTRONIC IGNITION ...

Page 2: ...atings and are valid only in Canada In the U S the National Fuel Gas Code ANSI Z223 1 1988 recommends for high altitude installations above 2 000 feet that the input rate be reduced 4 for each 1 000 feet above sea level See page 8 Figure 1 Size mm Qt natural standart 34 28 kW 1 20 diam 18 propane LP 0 2 000 ft 117 000 Btu hr 0 79 diam 18 natural high 30 85 kW 1 20 diam 18 propane LP 2 000 4 500 ft...

Page 3: ... or its connections will not result in damage to the area adjacent to the heater or to lower floors of the structure Note When such locations cannot be avoided it is recommended that a suitable drain pan adequately drained be installed under the water heater The pan must not restrict combustion air flow AIR REQUIREMENTS For safe operation sufficient air for combustion ventilation and dilution of f...

Page 4: ...ove or closet with minimum clearances to combustible construction of 0 mm from back 102 mm 4 inches from sides 305 mm 12 inches from top an bottom and 102 mm 4 inches from front A minimum of 305 mm 12 inches shall be allowed for maintenance of serviceable parts Clearance from vent is dependant upon the clearance rating of the venting material used that is type B 1 vent is approved for 1 inch clear...

Page 5: ...lue to the unit The adapter must be secured to the draft diverter outlet with a minimum of two screws Also in Canada the gas pressure regulator supplied with the water heater is factory preset to deliver gas to the water heater at the proper pressure setting for high altitude operation see PRESSURE REGULATION section of this manual table 1 on page 8 WARNING Failure to increase vent size on WR400 7...

Page 6: ...pe is clean on the inside To trap any dirt or foreign material in the gas supply line a drip leg must be incorporated in the piping The drip leg must be readily accessible and not subject to freezing conditions Install in accordance with the recommendations of serving gas supplier Joint compounds pipe dope shall be applied sparingly and only to the male threads of pipe joints Do not apply compound...

Page 7: ...n above on this label 2 The gas valve must be shut off by putting the ON OFF switch to position Wait five 5 minutes to clear out any gas If you smell gas STOP Follow B in the safety information above If you do not smell gas go to the next step 3 This water heater is equipped with a safety pilot burner and an automatic ignition control system 4 Set the ON OFF switch to the position In this position...

Page 8: ...s operating at full input Gas pressures read at burner test point D see fig 7 a will usually read 1 1 5 W C less than below Table 1 Appliance Regulator Pressure Setting Note The high altitude ratings listed are Canadian Gas Association high altitude ratings for the appliances and are only valid in Canada In the U S the National Fuel Gas Code ANSI 1 1988 recommends for high altitude installations a...

Page 9: ... electrode Pilot screen PILOT ORIFICE To clean the pilot burner and or the pilot orifice Turn off the gas to the unit Set the ON OFF switch to OFF position Remove the cover on the heater To do so pull of the temperature adjustment knob and unscrew and remove the plastic collar Pull main cover out toward you and lift up and out The pilot orifice should be cleaned or replaced Do not enlarge orifice ...

Page 10: ...mponent with new one and refit using the reverse of the procedure set out the table above Function check Flue gas safety device function check Disconnect flue pipe Replace with pipe about 50 cm long with sealed end Fit pipe vertically Start up appliance at rated output and set temperature control to maximum temperature Under those conditions the appliance should shut down after two minutes Remove ...

Page 11: ... valve at inlet and mix with cold water WATER IS NOT HOT ENOUGH 1 Temperature selection too low Change the setting Turn the temperature adjustment knob clockwise to the right Note This will decrease the activation flow rate 2 Water flow through the heater is higher than the capacity of the Bosch to heat it This can be due to too high water inlet pressure 60 psi max for best results or due to acid ...

Page 12: ...ure may be overpowered by a much higher cold water pressure which may cause the Bosch burners to shut down Make sure faucet aerators or shower heads are free of minerals Do not add any flow restrictor to the shower head 2 Cold water is mixing with the hot water between the Bosch and the outlet See 4 under NO SPARK AT THE PILOT 3 Inlet water pressure is erratic due to inadequate supply water pressu...

Page 13: ...lot assembly 3 Burner manifold gas pressure test nipple 4 Main gas burner 5 Pilot gas tubing 6 Led failure indicator 7 on off switch 8 Led operation indicator 9 Water valve 10 Temperature adjustment selector 11 Gas inlet gas pressure test nipple 3 1 4 10 11 2 9 8 6 7 5 ...

Page 14: ...14 6 720 606 560 Fig 16 INTERIOR COMPONENTS DIAGRAM AND PARTS LIST ...

Page 15: ...lve NG 8 707 011 917 15 Gas valve LPG 8 707 011 945 16 Diaphragm switch NG 8 708 504 021 16 Diaphragm switch LPG 8 708 504 049 17 Pilot electrovalve 8 708 501 249 18 Burner electrovalve 8 708 501 250 19 Cold water pipe 8 700 705 972 20 Hydro generator 8 707 406 043 21 Connecting pipe 8 700 705 947 22 Hot water pipe 8 700 715 080 23 Temperature limit 8 707 206 040 24 Water valve 8 707 006 353 25 Co...

Page 16: ...0 ...

Reviews: