![Bosch WR 11 B Installation Manual And Operating Instructions Download Page 15](http://html.mh-extra.com/html/bosch/wr-11-b/wr-11-b_installation-manual-and-operating-instructions_52918015.webp)
6720648592 (2014/05)
Adjustments (must be carried out only by qualified technicians) | 15
Minimum gas flow adjustment
6.3
Conversion to a different type of gas
Only use the original conversion kits.
The conversion must only be
performed by a qualified
technician. The original conversion kits are supplied with
assembly instructions.
The minimum gas flow adjustment is performed
automatically after the adjustment of the
maximum gas flow.
Natural gas H
Butane
Propane
Injector code
WR11
8708202113
(1,10)
8708202130
(0,70)
8708202124
(1,20)
8708202128
(0,72)
WR14
8708202113
(1,10)
8708202128
(0,72)
8708202116
(1,25)
8708202132
(0,75)
WR18
8708202115
(1,15)
8708202130
(0,70)
8708202116
(1,25)
8708202132
(0,75)
Connection
pressure
(psi)
WR11
WR14
WR18
3
2
3
MAX (psi)
WR11
8
,
2
7
2
,
1
3,5
WR14
8
,
2
2
,
1
3,5
WR18
5
5
,
2
3
0
,
1
3,25
Table 8
Burner pressure