Bosch Worcester Greenstore 180 Instruction Manual Download Page 8

SPECIFICATION SUMMARY

Materials

Shell - Stainless steel, inner - black carbon steel, outer

Coil - 15mm diameter copper

Greenstore cylinder is water tested to a pressure of 13 bar.

Insulation

Fire retardant mineral wool, nominal thickness 50mm.

Casework

Powder coated corrosion proof steel

Anode

Fitted (Aluminium)

Expansion Vessel

19 Litre size with 180 litre model

24 Litre size with 280 litre model

Control Settings

Pressure Reducing Valve 

- 3 bar

Expansion Relief Valve 

- 6 bar

Pressure and Temperature Relief Valve   - 7 bar / 95°C
Max inlet pressure (PRV) 

- 16 bar

Operating pressure (primary side) 

- 2.5 bar

Maximum operating pressure (DHW) 

- 3.0 bar

Expansion vessel pressure charge 

- 3.0 bar

Expansion relief valve setting 

- 6.0 bar

PART No. 

 CAPACITY

HEIGHT

WIDTH 

DEPTH

WEIGHT

kg empty

WEIGHT

kg  full

7 716 180 017

180 L

1520

600

650

97

387

7 716 180 018

280 L

1700

695 

695

136

596

All Dimensions are of the cased unit  and are in mm.

Approvals

- KIWA Approved to the Water Regulations
- KIWA Approved to Building Regulations’ G3 & L1

8

Worcester Bosch Greenstore

280 litre cylinder storage capacity

DHW side    - 280 litre
Primary side - 180 litre

280 litre Cylinder heat up time

From 15

o

C to 60

o

C - 163 minutes

Reheat time

For 70% volume - 53 minutes

Heat loss time

For 60

o

C to 53.6

o

C - 24 hours

180 litre cylinder storage capacity

 

DHW side    - 180 Litre
Primary side - 105 Litre

180 litre Cylinder heat up time

From 15

o

C to 60

o

C - 144 minutes

Reheat time

For 70% volume - 47 minutes

Heat loss time

For 60

o

C to 53.6

o

C - 24 hours

This is based on a 9kW Heat Pump input

Summary of Contents for Worcester Greenstore 180

Page 1: ...EENSTORE Indirect Unvented Cylinder with Solar Coil FOR USE WITH WORCESTER GREENSTORE SYSTEM HEATPUMP ONLY GB IE WORCESTER GREENSTORE 180 CYLINDER SOLAR COMPATIBLE WORCESTER GREENSTORE 280 CYLINDER SOLAR COMPATIBLE ...

Page 2: ...linder is supplied complete with all the necessary pre adjusted safety and control devices needed to connect to the cold water supply mains High quality controls have been selected to combine high flow rate performance with minimum pressure drop to allow the Greenstore cylinder to perform well in areas where there is a minimum dynamic working mains pressure of 1 5 bar Greenstore cylinders are KIWA ...

Page 3: ... flowrate is not being achieved SITING THE UNIT Outlets that are above or at some distance from the Greenstore cylinder can still be supplied with water Outlets above the Greenstore cylinder will reduce the outlet pressure available by 0 1 bar for every 1 metre of height difference Site the unit to minimise dead leg distances especially to the point of most frequent use The unit should be protected...

Page 4: ...tely after the incoming cold mains stopcock typically under the kitchen sink All outlets in the house will be at 3 bar and thus automatically balanced The expansion relief valve section must still be mounted just above the TPRV on the cylinder A 3 4 F 22mm compression adaptor will be needed not supplied HOT WATER PIPEWORK Run the first part of the hot water distribution pipework in 22mm This can be...

Page 5: ...minate in a safe place where there is no risk to persons in the vicinity of the discharge and positioned safely from electrical devices have a vertical section of pipe at least 300 mm long below the Tundish before any elbows or bends in the pipework installed with a continuous fall visible at both the tundish and the final point of discharge or where this is not possible or practically difficult the...

Page 6: ...R DRAINED OFF MAY BE VERY HOT DRAINING Isolate the unit from the cold mains Open a hot water tap at the lowest position in the building to reduce the pressure Remove the mains water inlet connection Attach a flexible hose to the connection on top of the cylinder ensuring the hose reaches to a level well below the unit The greater the difference in elevation the greater the flow rate and the maximum ...

Page 7: ...eat Pump HW Sensor cable entry 180 280 LITRE CYLINDERS WITH SOLAR COIL Air Vent Connecting hot water sensor GT3 Before carrying out any electrical connections ensure that the Heat Pump is isolated from the mains supply Remove the Heat Pump front cover and route the sensor cable from the back of the Heat Pump laying the sensor cable onto the cable tray Connect the sensor to terminals GT3X on the te...

Page 8: ...arge 3 0 bar Expansion relief valve setting 6 0 bar PART No CAPACITY HEIGHT WIDTH DEPTH WEIGHT kg empty WEIGHT kg full 7 716 180 017 180 L 1520 600 650 97 387 7 716 180 018 280 L 1700 695 695 136 596 All Dimensions are of the cased unit and are in mm Approvals KIWA Approved to the Water Regulations KIWA Approved to Building Regulations G3 L1 8 Worcester Bosch Greenstore 280 litre cylinder storage ...

Page 9: ...r WHERE IS OPERATING PRESSURE REDUCING VALVE SITUATED HAS THE EXPANSION VESSEL OR INTERNAL AIR SPACE BEEN CHECKED YES NO WHAT IS THE HOT WATER TEMPERATURE AT THE NEAREST OUTLET oC THERMAL STORES ONLY WHAT IS THE OPERATING SETTING OF THE PRESSURE REDUCING VALVE Where fitted bar WHERE IS THE PRESSURE REDUCING VALVE SITUATED WHAT STORE TEMPERATURE IS ACHIEVABLE oC WHAT IS THE MAXIMUM HOT WATER TEMPERA...

Page 10: ...ENGINEER NAME COMPANY NAME TEL No CORGI ID SERIAL No COMMENTS SIGNATURE SERVICE 3 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID SERIAL No COMMENTS SIGNATURE SERVICE 4 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID SERIAL No COMMENTS SIGNATURE SERVICE 5 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID SERIAL No COMMENTS SIGNATURE SERVICE 6 DATE ENGINEER NAME COMPANY NAME TEL No CORGI ID SERIAL No...

Page 11: ...Worcester Bosch Greenstore 11 NOTES NOTES ...

Page 12: ...of BBT Thermotechnology UK Ltd www worcester bosch co uk User and Installation Instructions Greenstore Cylinder Solar Compatible 8 716 113 377b 2007 01 EN CONTACT INFORMATION WORCESTER BOSCH GROUP TECHNICAL 08705 266241 SERVICE 08457 256206 SPARES 01905 752576 LITERATURE 01905 752556 TRAINING 01905 752526 SALES 01905 752640 WEBSITE www worcester bosch co uk ...