The appliance may be installed in any room subject to the
requirements of the current IEE regulations and, in Scotland, the
relevant electrical provisions of the Building Regulations with
respect to the installation of appliances in rooms containing
baths or showers.
If the appliance is installed in a room containing a bath or
shower, any switch or appliance control using mains electricity
must NOT be able to be touched by a person using the bath or
shower.
The appliance is NOT suitable for external installation.
The wall must be able to support the weight of the appliance.
Refer to Table 4.
The specified clearances must be available for installation and
servicing. Refer to Table 7 and Fig.2.
The appliance can be installed in a cupboard/compartment to
be used for airing clothes providing that the requirements of
BS6798 and BS5440/2 are followed. Refer to Section 2.4.
The clearance between the front of the appliance and the
cupboard/compartment door should be not less than 250mm.
LPG Installation. Refer to Section 1.10.
4. Siting The Appliance
6
Fig. 2. Appliance casing dimensions and
required clearances.
Side view
365mm
600mm*
30mm*
200mm*
10mm*
* Space required for installation and servicing
Front view
450mm
10mm*
225mm
150mm
850mm
Fig. 3. Appliance pipework connections
A
B
C
D
E
F
91
(A, B, C, D, and E)
61
A
B C D E
F
View on underside of appliance showing
connections
Rear of appliance
A
CH Flow
= 62.5
B
Cylinder Flow*
= 127.5
C
Cold In
= 192.5
D
Gas Inlet
= 257.5
E
Return
= 322.5
F
Safety Discharge
= 382.5
*Use with optional diverter valve
195
Screw driver required to operate Valves.
Valves shown closed.
(F)