Repairs
2017-05-22 / DIS 113_58300000186503_ara_en_c
Copyright by BSH Hausgeräte GmbH
Page 78 of 85
6.19
Replacing injection valves
Aqua Stop, supply hose, flow sensor and injection valves together
form a spare part which is replaced in case of a defect.
Prerequisite:
•
Aqua Stop has been removed.
•
Worktop has been removed.
6.19.1
Removing injection valve
1. Remove cable tie.
2. Remove electrical connections.
3. Loosen hose clips and remove hoses.
4. Remove the retaining screw
5. Disengage catch element (2).