Cleaning and servicing
en
37
Requirement:
1.
Because water may remain in the
drain pump, remove the pump cap
carefully.
2.
Clean the inside and the thread on
the pump cap and pump housing.
3.
Make sure that the impeller in the
drain pump can be turned.
4.
Insert the pump cap and screw it
on.
90°
The handle on the pump cap must
be in a vertical position.
5.
Insert the maintenance flap and
lock it into place.
1
2
6.
Close the maintenance flap.
Before the next wash
To prevent unused detergent from
flowing straight into the outlet in the
next wash, run the
Vidange
pro-
gramme after you have emptied the
drain pump.
1.
Turn on the tap.
2.
Insert the mains plug.
3.
Switch on the appliance.
4.
Pour 1 litre of water into compart-
ment II.
5.
Start the
Vidange
programme.
Cleaning the water outlet
hose at the siphon
If the water outlet hose at the siphon
is dirty or the detergent solution is
not being pumped out, you must
clean these.
1.
Switch off the appliance.
2.
Disconnect the appliance's mains
plug from the power supply.
3.
Loosen the hose clamp and care-
fully remove the water outlet hose.
Summary of Contents for WAJ20170MA