background image

18

en | Installing a Recessed Mount

AutoDome Junior

F.01U.201.538 | 1.0 | 2010.12

Mounting Guide

Bosch Security Systems, Inc.

11. Align trim ring so the four alignment posts (item 1, below) 

align with the recesses in the camera housing (item 2) and 

so the two safety screws align with the off center holes 

(item 3) on the locking clamps. 

Note: The two (2) sets of raised stand-off tabs (item 4) on 

each side of the trim ring align with the locking clamps.

Figure 3.12

Align Trim Ring

12. Snap trim ring into place. Ensure snaps are secure by 

attempting to lightly turn unit. Note: Unit should not turn.

13. Use the supplied T-10 Torx wrench to secure the trim 

ring’s two (2) safety locking screws to the mounting 

bracket. 

1

Alignment Tabs (four)

2

Align tabs to the recessed areas on the housing

3

Align safety locking screws to these connections

4

Stand-off Tabs (two)

Summary of Contents for VJR-A3-IC54

Page 1: ...IP 54 In ceiling Mount VJR A3 IC54 en Mounting Guide ...

Page 2: ......

Page 3: ...U 201 538 1 0 2010 12 Table of Contents 1 Important Safety Instructions 4 2 Unpacking 6 2 1 Parts List 6 3 Installing a Recessed Mount 7 3 1 Description 7 3 1 1 Additional Requirements 9 3 1 2 Preparing the Ceiling for Installation 9 3 1 3 Installing the Camera to the Mounting Plate 15 ...

Page 4: ...plug the unit during lightning storms or when unused for long periods 6 Adjust only those controls specified in the operating instructions 7 Do not overload outlets and extension cords as this can cause fire or electrical shock 8 Protect the plug and power cord from foot traffic or pinching at electrical outlets and at its exit from the unit 9 Operate the unit only from the type of power source in...

Page 5: ...ected by copyright Contact www BoschSecurity com DANGER High risk This symbol indicates an imminently hazardous situation such as Dangerous Voltage inside the product If not avoided this will result in an electrical shock serious bodily injury or death WARNING Medium risk Indicates a potentially hazardous situation If not avoided this could result in minor or moderate bodily injury CAUTION Low ris...

Page 6: ... returning the unit for service Save it for possible future use This installation should be made by qualified service personnel and conform to the National Electrical Code and applicable local codes 2 1 Parts List The following table lists the parts included with the VJR A3 IC54 AutoDome Junior IP54 rated In ceiling mount kit Quantity Part VJR A3 JW Junction Box 3 M4 7 x 8 Phillips Pan Head Machin...

Page 7: ... for proper performance and extended lifetime Follow the guidelines for optimum results with your camera Do not expose to direct sunlight or bright spotlights in operating and nonoperating conditions Avoid bright lights in the field of view of the camera Bright lights cause a smearing effect which is visible as white lines above and below the highlight Prolonged exposure to bright lights may cause...

Page 8: ...12 Mounting Guide Bosch Security Systems Inc Mounting Assembly The following illustrations shows the components of the recess mount Figure 3 1 AutoDome Junior with IP54 rated In ceiling Mount 1 VJR A3 JW Junction Box 2 Mounting Bracket 3 AutoDome Junior Camera 4 Trim Skirt ...

Page 9: ...10 Torx wrench Retaining ring with gasket supplied with AutoDome Junior camera kit Three 3 M3 5 x 6 Phillips flat head machine screws for use with the retaining ring supplied with AutoDome Junior camera kit VJR A3 SP support kit for VJR A3 IC54 mounting kit if mounting to a drop ceiling 3 1 2 Preparing the Ceiling for Installation To mount to a recess mount do the following 1 Determine a secure lo...

Page 10: ...kit is recommended supplied separately 4 Ensure that the gasket is attached to the retaining ring If the gasket and the retaining ring are separate a Locate the flat side of the gasket and the recessed side of the retaining ring b Thread the flat side of the gasket item 1 below onto the recessed side of the retaining ring item 2 The illustration below shows a cross section of the gasket on the ret...

Page 11: ... JW in which the external wires are to be routed and remove the plug from the knockout 7 Apply a 1 2 in 15 mm NPS fitting to the chosen knockout Ensure a water tight fitting to maintain the IP Environmental Protection Rating for the unit 8 Align the holes of the VJR A3 JW with the mounting bracket Ensure that the VJR A3 JW knockouts are not covered by the bracket arms 9 Thread the four 4 3 97 mm I...

Page 12: ...ms Inc 10 Attach the VJR A3 JW to the mounting bracket using the four 4 M4 x 16 Phillips Pan Head Machine Screws item 2 below Figure 3 4 Attach VJR A3 JW to Mounting Bracket 11 Align the holes of mounting plate with the VJR A3 JW junction box and attach with the three 3 M4 7 x 8 Phillips Pan Head Machine Screws ...

Page 13: ...drive screws item 1 below so that the clamping plates item 2 move freely Figure 3 6 Clamp Drive Screws and Plates 13 Insert the bracket through the hole in the ceiling Slide clamps out and down so that the ceiling drywall is captured in between the clamps and the bracket flange The ceiling drywall must have a maximum thickness of 41 7 mm 1 64 in and a minimum thickness of 12 7 mm 0 50 in ...

Page 14: ...ten both clamps using the clamp drive screws installed on the assembly and a 2 Phillips screwdriver Figure 3 8 Tighten Mounting Clamps NOTICE Over torquing the ceiling clamps can damage the clamp or ceiling Only tighten the clamp until it contacts the ceiling and you start to feel some resistance If using a power screwdriver set the torque level to the lowest setting ...

Page 15: ... Remove the screw from the Earth ground on the inside of the VJR A3 JW 3 Attach a user supplied ground wire to the Earth ground screw hole on the VJR A3 JW and secure with the screw 4 Attach the green grounding wire from the unit to the grounded screw hole on the VJR A3 JW using the attached captive screw washer 5 Route wires through the knockout on the VJR A3 JW NOTICE If you need to install the ...

Page 16: ...Plug the matching connectors from the camera into the mating connectors from the ceiling 8 Attach the camera to the mounting plate by inserting the vertical tab on the plate item 1 below into the recessed slot on the top of the camera dome Item 3 to the right of the safety locking screw item 2 Note Do not loosen the three brass buttons These brass buttons engage the slotted tabs on the mounting pl...

Page 17: ... the clockwise direction Then lock firmly into place as shown in the next illustration Figure 3 11 Attach Dome to Mounting Plate 10 Ensure unit is centered NOTICE The recessed mounting bracket is provided with an additional safety tether point item 1 Figure 3 11 To prevent injury attach a safety wire from a secure anchor point above the ceiling to this tether point ...

Page 18: ...amps Note The two 2 sets of raised stand off tabs item 4 on each side of the trim ring align with the locking clamps Figure 3 12 Align Trim Ring 12 Snap trim ring into place Ensure snaps are secure by attempting to lightly turn unit Note Unit should not turn 13 Use the supplied T 10 Torx wrench to secure the trim ring s two 2 safety locking screws to the mounting bracket 1 Alignment Tabs four 2 Al...

Page 19: ......

Page 20: ...Bosch Security Systems Inc 850 Greenfield Road Lancaster PA 17601 U S A www boschsecurity com Bosch Security Systems Inc 2010 ...

Reviews: