background image

en | Table of Contents 

AutoDome Pendant Arm Mount 

4.3 

Configuring Non-supervised Alarms (inputs 1 through 7) 

31 

4.3.1 

Configuring a Normally Open Non-supervised Alarm 

31 

4.3.2 

Configuring a Normally Closed Non-supervised Alarm 

32 

4.4 

Alarm Outputs 

32 

4.4.1 

Configuring a Dry Contact Relay 

32 

4.4.2 

Configuring an Open Collector Output 

32 

F.01U.250.238 | 1.0 | 2011.08 

Installation Guide 

Bosch Security Systems, Inc. 

                    Available from A1 Security Cameras 

    www.a1securitycameras.com email: [email protected]

Summary of Contents for VGA-PEND-ARM

Page 1: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com AutoDome Pendant Arm Mount VGA PEND ARM VGA PEND WPLATE en Installation Guide ...

Page 2: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Page 3: ...ables 19 3 3 1 Using Coaxial Cable to Transmit Video and Control 19 3 3 2 Using UTP to Transmit Video and Control 20 3 3 3 Using Ethernet to Transmit Video and Control 21 3 3 4 Using Multi mode Fiber Optic to Transmit Video and Control 21 3 3 5 Using a Fiber Optic Ethernet Media Converter to Transmit Video and Control 22 3 4 Control only Cables 22 3 4 1 Controlling the AutoDome via Biphase 22 3 4 ...

Page 4: ...pervised Alarm 31 4 3 2 Configuring a Normally Closed Non supervised Alarm 32 4 4 Alarm Outputs 32 4 4 1 Configuring a Dry Contact Relay 32 4 4 2 Configuring an Open Collector Output 32 F 01U 250 238 1 0 2011 08 Installation Guide Bosch Security Systems Inc Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Page 5: ... but a moist fluff free cloth or leather shammy may also be used Do not use liquid cleaners or aerosol cleaners 2 Water Do not use this unit near water for example near a bathtub washbowl sink laundry basket in a damp or wet basement near a swimming pool in an outdoor installation or in any area classified as a wet location To reduce the risk of fire or electrical shock do not expose this unit to ...

Page 6: ...e personnel when any damage to the equipment has occurred such as the power supply cord or plug is damaged exposure to moisture water and or inclement weather rain snow etc liquid has been spilled in or on the equipment an object has fallen into the unit unit has been dropped or the unit cabinet is damaged unit exhibits a distinct change in performance unit does not operate normally when the user ...

Page 7: ... installation of CATV systems SELV All the input output ports are Safety Extra Low Voltage SELV circuits SELV circuits should only be connected to other SELV circuits Because the ISDN circuits are treated like telephone network voltage avoid connecting the SELV circuit to the Telephone Network Voltage TNV circuits System ground Safety ground System video ground is indicated by the symbol Safety po...

Page 8: ...le redundant recording systems and a procedure to back up all analog and digital information Copyright This manual is the intellectual property of Bosch Security Systems and is protected by copyright All rights reserved Trademarks All hardware and software product names used in this document are likely to be registered trademarks and must be treated accordingly Note This manual has been compiled w...

Page 9: ...ers Mounting Plate VGA PEND WPLATE Optional Mounting Accessories The following table lists the optional parts you may need for attaching a Pendant Arm to a Wall Corner or Mast Mounting Options Part Numbers Pendant Arm with wiring no power supply VGA PEND ARM Pendant Arm with wiring no power supply for a Pressurized Environmental Housing VGA PRES ARM Corner Mount Plate VG4 A 9542 Mast Mount Plate V...

Page 10: ...tly earthed metal conduits 3 Route all rough wiring including power control video coax alarms I O relay I O and fiber optic cabling Refer to Section 3 Cable and Wire Standards page 19 for video and control protocol methods 4 Analog AutoDome If you plan to use the RS232 or RS485 protocol to control the AutoDome refer to Section 3 4 2 Controlling the AutoDome via the RS232 Protocol page 24 for instr...

Page 11: ...te conduit All video control and alarm wires may be routed through a second conduit to the power supply then to the VGA PEND ARM or can be routed directly to the VGA PEND ARM through a conduit WARNING External interconnecting cables are to be installed in accordance to NEC ANSI NFPA70 for US application and Canadian Electrical Code Part I CSA C22 1 for CAN application and in accordance to local co...

Page 12: ...onnecting the power to a 24 VAC AutoDome WARNING A stud diameter of 6 4 mm 1 4 inch to 8 mm 5 16 inch able to withstand a 120 kg 265 lb pull out force is recommended The mounting material must be able to withstand this pull out force For example 19 mm 3 4 inch minimum for plywood 1 For a Corner installation a Secure the Corner Plate to the wall corner using four 4 studs not included b Secure the M...

Page 13: ...ounting Plate through the empty conduit hole as shown below 3 Ensure that the mounting plate is secure Attach the Pendant Arm to the Mounting Plate The bottom hinge pin of the Pendant Arm is provided with a Hinge Pin Stop to hold the hinge open while attaching the arm to the Mounting Plate 1 Compress the bottom hinge pin by pushing the pin lever downward and rotating it behind the Hinge Pin Stop F...

Page 14: ...late Refer to Figure 2 2 above for an illustration 4 Once you have the hinges aligned release the top hinge pin to engage its mating hinge on the Mounting Plate Then release the bottom hinge pin from the Hinge Pin Stop to lock the Pendant Arm to the Mounting Plate Route and Connect Wires to a Power Supply Box The illustration below depicts the power and control cables connected to the Pendant Arm ...

Page 15: ...nput conduit holes 4 Connect the incoming 24 VAC power wires to the 5 pin 24 VAC Power In mating connector supplied with the Mounting Plate kit for the Dome and for the Heater CAUTION You must route the main power supply through a 120 230 VAC transformer VG4 A PSU1 or VG4 A PSU2 power supply box before connecting the power to a 24 VAC AutoDome 5 Attach the grounding spade from the 5 pin mating con...

Page 16: ... to the UTP Video Ethernet cable cable 5 Refer to Section 3 Cable and Wire Standards page 19 for detailed wire and connection information 15 Connect the outgoing alarm wires to the flying leads coming from the 4 pin Alarm Outputs cable cable 6 16 Connect the incoming alarms wires to the flying leads coming from the 6 pin Alarm Inputs cable cable 7 17 Analog AutoDome Connect the incoming serial com...

Page 17: ...m 1 Tilt the bottom of the dome toward the pendant arm base and place the mounting hook located on top of the dome housing over the recessed hinge pin of the arm a b Figure 2 5 Attach Pendant to Arm 1 Tilt up 2 Hook and drop 2a Recessed Hinge Pin 2b Dome Connector 3 Rotate down to engage dome connector 4 Tighten the two 2 mounting screws to a minimum torque of 10 12 N m 90 105 in lbs Bosch Securit...

Page 18: ...feel any resistance when rotating the dome housing or when engaging the connector stop immediately and start over 4 Hold the Pendant housing in position while tightening the two 2 5 mm Allen head mounting screws on top of the housing to 10 12 N m 90 105 in lbs CAUTION You must tighten the two mounting screws to a minimum torque of 10 12 N m 90 105 in lbs to ensure a proper seal between the arm and...

Page 19: ...ndard heater module Add Add 16 W if using VG4 SHTR XT kit 3 3 Video and Control Cables 3 3 1 Using Coaxial Cable to Transmit Video and Control CAUTION 600 Series AutoDome If you are using coaxial cable to transmit video and data between the AutoDome and the head end you must use the coax cable with ferrite included in the AutoDome packaging You must connect the incoming coax cable from the head en...

Page 20: ...ly a Coax to UTP cable converter is required at the head end of the system Bilinx control data can also be sent over the same two video wires 1 2 Bilinx is a Bosch 2 way communication protocol that allows remote control configuration and updates over a passive UTP cable VG5 Series AutoDomes feature cable compensation or Pre Comp which extends the normal range of control from the head end WARNING D...

Page 21: ...c to Transmit Video and Control Fiber Optic kits available for AutoDome 100 and 600 Series cameras transmit both video and Biphase control over an analog singlemode or multimode fiber Multimode Fiber Type 50 125 µm 62 5 125 µm low loss multimode glass fiber Maximum Distance 4 km 2 5 miles Minimum Bandwidth 20 MHz Video 850 nm Control 1300 nm Requirement Bosch LTC 4629 Fiber Receiver at controller ...

Page 22: ...fiber standard ITU T G 651 Fiber Type SMF 8 10 125 µm SMF Must meet or exceed fiber standard ITU T G 652 Maximum Distance 60 km 37 3 miles Requirement Media converter receiver CNFE2MC IN at controller end of system Terminal Connection Duplex LC or Single SC 3 4 Control only Cables 3 4 1 Controlling the AutoDome via Biphase Shielded 2 wire half duplex multi drop 5000 ft cable limit Biphase is the s...

Page 23: ...n where multiple domes are connected in series the 100 Ω resistor must be removed from all but the last dome You can daisy chain a maximum of four 4 AutoDomes 100 Ω Figure 3 3 Connections for a Daisy Chain Configuration 1 C Biphase 9 Dome 3 2 C Biphase 10 Dome 2 3 Earth Ground 11 Dome 1 4 RxD 12 Head End Biphase 5 TxD 13 C Biphase 6 Signal Ground 14 C Biphase 7 Last Dome Data In Out 15 Shield 8 P1...

Page 24: ...After making the wire connections for RS232 operation reposition the slide switch located on the CPU Module to the camera head inward and away from the LEDs Wire Type 3 wire TXD RXD common Distance 15 m 50 ft Maximum Baud Rate 57 6 Kb Voltage 15 V Termination 100 Ω Slide Switch Away from LEDs factory default Figure 3 4 1 2 3 4 5 6 Connections for RS232 Operation C Biphase C Biphase Earth Ground Rx...

Page 25: ...ire shield must be tied to signal at both ends if 2 wire twisted pair is used After connecting the wires for RS485 operation make sure the slide switch on the main board to the camera head is positioned toward the LEDs default CAUTION Bosch recommends that multiple RS485 connections be arranged as a connected series of point to point multi dropped nodes as a line or as a bus It is not recommended ...

Page 26: ... from the pendant housing Fiber Optic Module with an RS232 RS422 Controller An AutoDome with a fiber optic module is prewired to operate with Biphase signals only This section describes the procedures necessary to control a VG5 series AutoDome fitted with a fiber optic kit using an RS232 controller or a Pelco RS422 controller To control a VG5 Series Autodome from an RS232 or from a Pelco RS422 con...

Page 27: ...five wires from the green Serial Communications wire mating connector Ensure that the insulation covers each wire to avoid wires from touching 5 Cut back the insulation on the blue ground wire and on the green RxD wire enough to be able to connect these wires back into the P106 connector 6 Connect the blue ground wire to the C pin on the P106 connector 7 Connect the green RxD wire to the C pin on ...

Page 28: ...apable of receiving line input audio signals and transmitting it over a network The audio signal is transmitted one way and in sync with the video signals Audio Line Input Specifications Max Input Voltage 5 5 Vpp Impedance 9K Ω Sample Rate 8 K Hz 16 Bit mono Shield Bare copper braid 95 coverage Internal gain level adjustment is available Wire Specifications Wire Type Coax3 recommended Distance 10 ...

Page 29: ...s the connections for audio over an IP network Figure 3 10 Connections for audio over an Ethernet network 1 C Biphase 7 AutoDome Data In Out 2 C Biphase 8 P105 P106 Connector 3 Earth Ground 9 Audio Out 4 RxD 5 TxD 6 Signal Ground NOTICE Refer to the VG5 700 Series AutoDome User Manual for configuring and using audio over an IP Ethernet network Bosch Security Systems Inc Installation Guide F 01U 25...

Page 30: ...hort or a break in the alarm s circuit can trigger the tamper signal Configuring Supervised Alarms inputs 1 and 2 To configure Alarm 1 or 2 pin 5 or 6 for supervision you must install a 2 2 K end of line resistor in the circuit Then you program the alarms through the AutoDome main menu to either Normally Open Supervised N O S or Normally Closed Supervised N C S NOTICE Only Alarms 1 and 2 pins 5 or...

Page 31: ...up and set Alarm Input 1 Dry Contact 3 Dome Connector 2 Alarm 1 or 2 only Pin 5 or 6 4 Ground Pin 7 to N C S See the table below for contact and condition details AutoDome Programmed N C S Contact Alarm Condition Open Alarm Closed Normal Short Tamper 4 3 Configuring Non supervised Alarms inputs 1 through 7 You can configure alarms 3 through 7 as non supervised Normally Open N O or Normally Closed ...

Page 32: ...AutoDome incorporates two 2 types of alarm outputs a dry contact relay and three 3 open collector outputs or transistor outputs 4 4 1 Configuring a Dry Contact Relay The dry contact relay acts like an on off switch It has a maximum voltage rating of 2 A 30 DC 1 Connect the appropriate stripped wire to the AutoDome COM connector 2 Connect the appropriate stripped wire to the N O or N C connector de...

Page 33: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Page 34: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Page 35: ...Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Page 36: ...urity Systems Inc 850 Greenfield Road Lancaster PA 17601 U S A www boschsecurity com Bosch Security Systems Inc 2011 Available from A1 Security Cameras www a1securitycameras com email sales a1securitycameras com ...

Reviews: