20
| English
Digital inspection camera
UniversalInspect
Rated voltage
V=
6
Non-rechargeable batteries (alkaline manganese)
4 × 1.5 V LR6 (AA)
Operating temperature
°C
–10 to +50
Storage temperature (without batteries)
°C
–20 to +70
Relative air humidity
%
5–95
A)
Length of camera cable
mm
950
Smallest bend radius of camera cable
mm
30
Camera head diameter
mm
8
Display resolution
320 × 240
Approx. operating time
h
4
Weight according to EPTA-Procedure 01:2014
(With batteries, without protective bag, without ac-
cessories)
kg
0.39
Dimensions (length × width × height)
mm
161 × 70 × 41
Protection rating of camera head and camera cable
IP 67
Protection rating of housing
–
A) Free of condensation
For clear identification of your inspection camera, see the serial number
(15)
on the type plate.
Assembly
Power supply
The inspection camera can be operated with commercially available batteries.
To open the battery compartment cover
(17)
, press on the locking mechanism
(16)
and
remove the battery compartment cover
(17)
. Insert the batteries. When inserting the
batteries, ensure that the polarity is correct according to the illustration on the inside of
the battery compartment.
Always replace all the batteries at the same time. Only use batteries from the same man-
ufacturer and which have the same capacity.
u
Remove the batteries from the inspection camera when not using it for longer
periods.
The batteries can corrode and self-discharge during prolonged storage.
Note:
The ribbon
(20)
in the battery compartment is used to conveniently remove the
batteries.
1 609 92A 69V | (26.01.2021)