
6 720 801 512 (2015/05)
Tronic 1000 T
Maintenance (only for authorized technicians) | 79
▶ Completely drain the appliance (
section 5.4).
▶ Remove the lid of the appliance, by unscrewing the 4
screws (
Fig. 12).
Fig. 12
Screws position
▶ Switch off the circuit breaker feeding the appliance.
▶ Disconnect the connecting cables to the thermostat.
▶ Unscrew the flange fastening nut (Fig. 13, [1]).
▶ Remove the flange from the inside of the appliance
(Fig. 13, [2]).
▶ Verify the magnesium anode and replace it if necessary.
Fig. 13
Access and identifying internal components
[1] Fastening screw
[2] Flange
[3] Magnesium anode
[4] Safety and control thermostat
6.2.3 Periodic cleaning
▶ Turn off all hot water taps.
▶ Inform all residents of the danger of burns
▶ Position the thermostat on the maximum position, turn the
temperature selector to the left up to the knocker (
Fig. 9).
▶ Wait until the indicator turns off.
▶ Open all the hot water taps, starting with the nearest one to
the furthest one from the appliance, and purge all the hot
water from inside the appliance, at least 3 minutes.
▶ Turn off all the hot water taps, and position the thermostat
on the normal working position.
6.2.4 Long standing (non working)
▶ Switch off the electric current to the appliance.
▶ Drain the appliance completely.
▶ Fill the appliance until the water comes out from all the hot
water taps.
▶ Turn on the appliance to the electric current.
6.3
Safety thermostat
The appliance is equipped with an automatic safety
thermostat. If for any reason the water temperature inside the
appliance exceeds the safety limit, the switch will trigger and
cut all electric current supplying the appliance, thus avoiding
any accidents.
6720643873-10.1V
3
2
1
6720643873-11.1V
4
DANGER:
Burn risk!
During the periodic cleaning process the hot
water may cause serious burns.
▶ Carry out this operation outside
working hours.
After a long period of inactivity you should
change the water inside the appliance (more
than 3 months).
DANGER:
The reactivation of the appliance
should only be done by an authorized
technician!
The action to manually re-start or reactivate
should only be done once the cause of
which initiated this action has been
identified and rectified.To reactivate the
device::
▶ Press the button firmly (Fig. 14).