Installation (only for approved contractors)
13
Tronic 5000 – 6721830067 (2021/06)
Fig. 8
[0] Protection zone 0
[1] Protection zone 1
[2] Protection zone 2
[2*] Without the wall, protection zone 2 must extend to
600 mm away from the bath
[A]
600 mm radius from the bath or shower
5.3
Unpack and remove the cover of the appliance
NOTICE
Risk of damage to the appliance!
In the event of transportation damages,
▶ Do not install the appliance.
Before carrying out any installation,
▶ Pay attention to the instructions given in this manual.
▶ Perform the installation of the appliance according to the
following images.
▶ Unpack the appliance.
▶ Dispose of the packaging according to the recycling
systems applicable in the country.
▶ Remove the front fascia of the appliance.
Fig. 9
Remove the front fascia
▶ Loosen the fixing screw at the front of the appliance.
Fig. 10
Remove the screw